EVALUASI PERFORMA BOILER TYPE DG 1025/182 – II 13 UNIT 10 PLTU 1 JAWA TENGAH REMBANG PADA KONDISI 300 MW DENGAN METODE LANGSUNG ( EVALUATION PERFORMANCE OF BOILER TYPE DG1025/18.2 - II 13 IN UNIT 10 PLTU 1 JAWA TENGAH REMBANG AT 300 MW LOAD USING DIRECT METHOD )

Pranata, Hastony Indra and Murni, Moch (2013) EVALUASI PERFORMA BOILER TYPE DG 1025/182 – II 13 UNIT 10 PLTU 1 JAWA TENGAH REMBANG PADA KONDISI 300 MW DENGAN METODE LANGSUNG ( EVALUATION PERFORMANCE OF BOILER TYPE DG1025/18.2 - II 13 IN UNIT 10 PLTU 1 JAWA TENGAH REMBANG AT 300 MW LOAD USING DIRECT METHOD ). Undergraduate thesis, D3 Kerjasama PT. PLN - Fakultas Teknik Bidang Mesin.

[img]
Preview
PDF
172Kb
[img]
Preview
PDF
35Kb
[img]
Preview
PDF
641Kb
[img]PDF
Restricted to Repository staff only

2286Kb
[img]PDF
Restricted to Repository staff only

275Kb
[img]
Preview
PDF
29Kb

Abstract

Boiler merupakan bagian terpenting dalam pembangkit, apabila unjuk kerja boiler menurun maka unjuk kerja dari pembangkit juga akan menurun sehingga perlu adanya pengkajian dan penanganan tentang studi dan analisis unjuk kerja Boiler PLTU 1 Jawa Tengah. Pengkajian ini bertujuan agar mengetahui besarnya tingkat penurunan effisiensi serta langkah yang dapat diambil untuk mengatasi tersebut. Dari hasil perhitungan dengan menggunakan metode langsung (direct) didapatkan bahwa effisiensi Boiler Unit 10 PLTU 1 Jawa Tengah Rembang tertinggi yaitu pada awal operasi dengan effisiensi sebesar 82,27% dan pada bulan Maret 2013 didapatkan rata-rata effisiensi sebesar 72,2% sehingga didapatkan penurunan effisiensi sebesar 10,07%. Dengan penurunan effisiensi yang cukup tinggi perlu adanya evaluasi terhadap kesempurnaan pembakaran serta pemeriksaan komponen Boiler agar effisiensi meningkat serta menghemat biaya produksi. Serta dari perhitungan sebaiknya Boiler dioperasikan pada kondisi beban 315 MW karena effisiensi dari Boiler yang tinggi dibanding pada kondisi beban yang lain, selain itu dengan effisiensi Boiler yang tinggi dapat menghemat dari segi biaya produksi. dalam kenyataannya untuk beban puncak pada Boiler unit 10 PLTU 1 Jawa Tengah Rembang untuk saat ini hanya pada kondisi beban 300 MW hal ini dipengaruhi oleh permintaan P3B sebagai penyalur energi listrik ke konsumen. Kata kunci : Effisiensi, metode langsung Boiler is an important part in the generation, boiler performance decreases when the performance of the plant will also be decreased so that the need for assessment and management of the study and analysis of the performance of the Power Plant Boiler 1 Central Java. This assessment intended to make determine the level of decrease efficiency and steps can be taken to overcome them. From the results of calculations using the direct method, found that the efficiency of Boiler Unit 10 PLTU 1 Central Java Rembang highest at the beginning of the operation efficiency of 82.27% and March 2013 found an average efficiency of 72.2% so we get decreased efficiency of 10.07%. With sufficient high efficiency decreased need for evaluation perfection combustion and examination components boiler, in order to increase efficiency and reduce costs. As well as of the calculation should Boilers operated at 315 MW load conditions due to the high efficiency of the boiler load conditions than in others, but that with a high efficiency boiler could save in terms of costs of production. in fact for the peak load on the boiler unit 10 Central Java Power Plant 1 Apex for today only at 300 MW load conditions it is influenced by demand P3B as electrical energy supplier to the consumer. Keywords: Efficiency, Direct method

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Faculty of Engineering > Diploma in Mechanical Engineering
Faculty of Engineering > Diploma in Mechanical Engineering
ID Code:41158
Deposited By:INVALID USER
Deposited On:20 Dec 2013 10:47
Last Modified:20 Dec 2013 10:47

Repository Staff Only: item control page