PENGARUH HYDRAULIC LOADING RATE (HLR) DAN KONSENTRASI INFLUEN TERHADAP PENYISIHAN PARAMETER BOD, COD DAN NITRAT PADA PENGOLAHAN AIR LIMBAH DOMESTIK CAMPURAN (GREY WATER DAN BLACK WATER) MENGGUNAKAN REAKTOR UASB

Sita Ningrum, Ardina (2012) PENGARUH HYDRAULIC LOADING RATE (HLR) DAN KONSENTRASI INFLUEN TERHADAP PENYISIHAN PARAMETER BOD, COD DAN NITRAT PADA PENGOLAHAN AIR LIMBAH DOMESTIK CAMPURAN (GREY WATER DAN BLACK WATER) MENGGUNAKAN REAKTOR UASB. Undergraduate thesis, Universitas Diponegoro.

[img]PDF
1061Kb

Abstract

ABSTRACT In this study using a mixture of domestic wastewater. Parameters to be researched is the Biological Oxygen Demand (BOD5), Chemical Oxygen Demand (COD) and nitrate-nitrogen (NO3-N). Alternative anaerobic treatment is to use UASB (upflow Anaerobic Sludge Blanket) . This study performed a variation of Hydraulic Loading Rate (HLR) and the influent concentration to obtain the optimum conditions on an UASB reactor laboratory scale for removal BOD5, COD and NO3-N in a mixture of domestic waste water (grey water and black water). Pollutant removal efficiency by varying the influent concentration and HLR for BOD5 was about 57% -76%, for COD was about 59% -69% and NO3-N was about 75% -98%. The results is the lower influent concentration will decrease removal efficiency that occurred on the parameters of BOD5, COD and NO3-N. The maximum removal efficiency on the parameters BOD5 and COD occurs when HLR low at 0.025 m3/m2/hour or 6.94 x 10-6 m / s. While the maximum removal efficiency of NO3-N occurred when HLR high 0.05 m3/m2/hour or 1.4 x10-5 m / s. Removal for BOD5 optimum occurs at low concentrations are 419 mg / l with a variation HLR of 0.05 m3/m2/hour or 1.4 x10-5 m / s, for COD occurred at low concentrations are 878 mg / l with a variation HLR of 0.025 m3/m2/hour or 6.9 x10-6 m / s, and NO3-N concentration was occur in the 36 mg / l with a variation HLR of 0.033 m3/m2/hour or 9.2 x10-6 m / s. The results of treatment using UASB still above the standards that should UASB be used as a secondary treatment to obtain the effluent below quality standart. Keywords: mixture domestic wastewater, UASB, concentration, Hydraulic Loading Rate (HLR)

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TD Environmental technology. Sanitary engineering
Divisions:Faculty of Engineering > Department of Environmental Engineering
Faculty of Engineering > Department of Environmental Engineering
ID Code:40886
Deposited By:INVALID USER
Deposited On:05 Dec 2013 09:13
Last Modified:05 Dec 2013 09:13

Repository Staff Only: item control page