Widodo , Agus (2000) Pemakaian prinsip Rambatan Cahaya pada Medium Transparan untuk Rancang Bangun pendektesian Cairan. Undergraduate thesis, FMIPA UNDIP.
PDF Restricted to Repository staff only 2724Kb | ||
| PDF 18Kb | |
| PDF 354Kb | |
| PDF 484Kb | |
| PDF 380Kb | |
| PDF 698Kb | |
| PDF 462Kb | |
PDF Restricted to Repository staff only 509Kb | ||
| PDF 342Kb | |
| PDF 331Kb | |
| PDF 811Kb |
Abstract
Telah dilakukan perancangan dan pembuatan sistem deteksi cairan dengan memanfaatkan rambatan cahaya pada medium transparan. Peralatan ini berfungsi untuk mendapatkan informasi keberadaan cairan terutama pa.da bagian yang sulit dijangkau Berta keberadaan cairan tersebut dapat mengganggu efisiensi kerja suatu peralatan. Pengamatan dilakukan terhadap perbedaan tegangan keluaran sensor saat kaca kering dan basah. Selanjutnya sinyal tegangan ini dikirim pada penguat dan komparator untuk dibandingkan dengan tegangan acuan pada komparator. Hasil perbandingan ini keinudia.n ditampilkan oleh indikator dengan menyala atau padanmya LED. Hasil yang didapat dari pengujian dengan ketebalan kaca. 1,92 ± 0,01 mm, sudut datang 300 dan jarak pemancar sampai dengan kaca 5,85 mm serta jarak yang sama antara kaca sampai dengan sensor, diperoleh basil keluaran yaitu menyalanya LED indikator pada saat permukaan luar kaca. kering dan pa.dam pada saat terd.apat cairan di permukaan luar kaca. It has been designed and make the liquid detection sistem exploit the light propagation on the transparent medium. This equipment uses to get the infbrmation of being civilized liquid that particulary on the imposible to be reach position and if the liquid prate will be distrubed work efficiency of an equipment. The observed has been for different censor produced voltage since dry condition glass and wet condition glass. Later, this voltage signal sent to operasional apiifier and comparator for beyond compared comparator reference voltage. Then the comparason product sent to indicator have the shape of flame and extinguished of indicator LED. The result of observation with .thicknees of glass is 1,92 ± 0,01 mm, the incident angle is 30°, the distance between the fountain to medium is 5,85 mm and the same distance of medium to sensor, the out-put of the equipment is the flame of indicator LED since out of the glass surface was thy and the extinguase of indicator LED when be found the liquid on the out of glass surface.
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Science and Mathematics > Department of Physics |
ID Code: | 30491 |
Deposited By: | Mr UPT Perpus 1 |
Deposited On: | 31 Oct 2011 14:43 |
Last Modified: | 31 Oct 2011 14:43 |
Repository Staff Only: item control page