Perbandingan respon dosis radiasi pada Film Badge dan dosimeter Elektronik dengan alat ukur standard Dosimeter Farmer

Tiswati, Kandi Ayu (1999) Perbandingan respon dosis radiasi pada Film Badge dan dosimeter Elektronik dengan alat ukur standard Dosimeter Farmer. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

1755Kb
[img]
Preview
PDF
17Kb
[img]
Preview
PDF
347Kb
[img]
Preview
PDF
503Kb
[img]
Preview
PDF
354Kb
[img]
Preview
PDF
896Kb
[img]
Preview
PDF
382Kb
[img]PDF
Restricted to Repository staff only

462Kb
[img]
Preview
PDF
331Kb
[img]
Preview
PDF
333Kb
[img]
Preview
PDF
502Kb

Abstract

Telah dilakukan penelitian untuk membandingkan penerimaan dosis radiasi antara film badge dengan dosimeter elektronik dengan alas ukur standard dosimeter Farmer. Penelitian ini dilakukan dengan memberikan paparan radiasi gamma 137Cs sebesar 10, 20, 30, 40, 50, 75, 100, dan 200 mR terhadap film badge, dosimeter elektronik, dan alat ukur standard pada jarak sate meter dan kondisi penyinaran yang sama. Data dianalisis dengan menggunakan uji ANOVA dan dilanjutkan dengan uji Duncan. Hasil penelitian menunjukkan ada perbedaan nyata untuk besar dosis radiasi pada film badge, dosimeter elektronik dan alat ukur standard. Perbedaan film badge terhadap alat ukur standard sebesar 8,98 %, dan dosimeter elektronik terhadap alat ukur standard sebesar 8,70 %. Perbedaan dosis ini cukup memadai untuk tingkat proteksi radiasi, dengan perbedaan kurang dari 20 %. A research to compare the receiving radiation dose between film badge with electronic dosemeter by farmer dosemeter as standard measurement device has been performed. The research was curried out with given radiation gamma 137Cs exposure of 10, 20, 30, 40, 50, 75, 100 and 200 Ira to film badge, electronic dosemeter and standard measurement device on same distance on one meter and exposure conditions. The data were analyzed with using of ANOVA test and continued with Duncan test. The research result shown the real differences for radiation dose on film badge, electronic dosemeter and standard measurement device. The difference film badge with standard measurement device was about 8,98 % and electronic dosemeter with standard measurement device about 8,70 %. This dose difference was enaugh for radiation protection level, with difference less than 20 %.

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QC Physics
Divisions:Faculty of Science and Mathematics > Department of Physics
ID Code:30466
Deposited By:Mr UPT Perpus 1
Deposited On:31 Oct 2011 12:41
Last Modified:31 Oct 2011 12:41

Repository Staff Only: item control page