Dias Wahyu Afianto, Syahrizal (2019) RANCANG BANGUN SIMULATOR MANUVER BEBAN RATIO 4 KEYPOINT BERBASIS ARDUINO MEGA 2560 DENGAN TAMPILAN HUMAN MACHINE INTERFACE (HMI) PADA JARINGAN TEGANGAN MENENGAH 20KV. Undergraduate thesis, undip vokasi.
| PDF (COVER) 113Kb | |
| PDF (KATA PENGANTAR) 154Kb | |
| PDF (DAFTAR ISI) 173Kb | |
| PDF (ABSTRAK) 87Kb | |
| PDF (DAFTAR GAMBAR) 171Kb | |
| PDF (DAFTAR TABEL) 85Kb | |
| PDF (BAB I) 173Kb | |
| PDF (BAB II) 1090Kb | |
PDF (BAB III) Restricted to Repository staff only 571Kb | ||
PDF (BAB IV) Restricted to Repository staff only 2058Kb | ||
PDF (BAB V) Restricted to Repository staff only 968Kb | ||
| PDF (BAB VI) 156Kb | |
| PDF (DAFTAR PUSTAKA) 94Kb | |
| PDF (DAFTAR LAMPIRAN) 81Kb |
Abstract
Salah satu indikator dari keandalan sistem distribusi tenaga listrik adalah stabilnya pasokan listrik kepada konsumen. Untuk menjaga kestabilan penyaluran listrik kepada konsumen dibutuhkan beberapa faktor yang dapat menjaga kestabilan penyaluran listrik, diantaranya adalah peralatan switching yang memadai serta susunan yang baik pada peralatan switching tersebut. Peralatan switching yang terpasang dalam jaringan dan dapat diintegrasikan dengan Scada (Supervisory Control and Data Acquisition) disebut keypoint. Dalam menjaga kestabilan pasokan listrik, implementasi 4 keypoint berpengaruh dalam menekan daerah padam di pelanggan pada suatu jaringan. Hal ini dikarenakan pada sistem 4 keypoint memiliki keypoint yang cukup untuk melakukan manuver jaringan ataupun joint dengan feeder lain ketika feeder utama mengalami gangguan atau pemeliharaan. Arduino Mega 2560 difungsikan sebagai otak dari sistem pada simulator mengenai 4 keypoint ini. ZMCT103C digunakan sebagai sensor arus yang ada pada masing-masing feeder. Peralatan switching berupa PMT dan LBS (Load Break Switch) disimulasikan dengan menggunakan relai. SCADA (Supervisory Control And Data Acquisition) berupa Human Machine Interface (HMI) hanya difungsikan sebagai monitoring tampilan arus pada setiap feeder atau PMT sehingga monitoring dapat dilakukan dari jarak jauh dan tidak dapat digunakan sebagai kontrol jarak jauh atau remot. Keypoint dapat memisahkan section yang megalami gangguan dan section normal. Kata Kunci : Arduino Mega 2560, Keypoint, Peralatan Switching, Scada One indicator of the reliability of the power distribution system is the stable supply of electricity to consumers. To maintain the stability of electricity distribution to consumers, several factors are needed to maintain the stability of electricity distribution, including adequate switching equipment and a good arrangement of the switching equipment. Switching equipment that is installed in a network and can be integrated with Scada (Supervisory Control and Data Acquisition) is called a keypoint. In maintaining the stability of electricity supply, the implementation of 4 keypoints has the effect of suppressing outages in customers on a network. This is because the 4 keypoint system has enough keypoints to maneuver or joint with other feeders when the main feeder is experiencing trouble or maintenance. Arduino Mega 2560 functions as the brain of the system in this 4 keypoint simulator. ZMCT103C is used as a current sensor in each feeder. The switching equipment in the form of PMT and LBS (Load Break Switch) is simulated using a relay. SCADA (Supervisory Control And Data Acquisition) in the form of Human Machine Interface (HMI) only functions as monitoring the flow display on each feeder or PMT so that monitoring can be done remotely and cannot be used as remote control or remote. Keypoint can separate sections that are experiencing interference and normal sections. Keywords: Arduino Mega 2560, Keypoint, Switching Equipment, Scada
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Faculty of Engineering > Diploma in Electrical Engineering Faculty of Engineering > Diploma in Electrical Engineering |
ID Code: | 77701 |
Deposited By: | INVALID USER |
Deposited On: | 09 Oct 2019 14:46 |
Last Modified: | 09 Oct 2019 14:46 |
Repository Staff Only: item control page