KONDISI TERMAL PADA PENGHAWAAN ALAMI DI RUANG TUNGGU UTAMA STASIUN SEMARANG TAWANG

Faza Surya Rusyda, Hana and Setyowati, Erni and Hardiman, Gagoek (2018) KONDISI TERMAL PADA PENGHAWAAN ALAMI DI RUANG TUNGGU UTAMA STASIUN SEMARANG TAWANG. Universitas Kebangsaan Bandung, Universitas Kebangsaan Bandung.

[img]
Preview
PDF - Published Version
4Mb

Abstract

Thermal comfort is a state of mind that expresses a user's satisfaction with thermal conditions. This study focuses on the design of natural ventilation which is one of the efforts to reduce the heat that exists in the building, especially in maintaining the thermal conditions. Tawang Train Station, Semarang has a natural ventilation design that is still maintained especially in the waiting room. This study aims to determine the thermal conditions of the design of ventilation using the theory of Mom and Wiseborn, SNI 03-6572- 2001, and Olgyay chart. This research method uses quantitative and field measurements were done for 14 hours to know the movement of air, temperature, humidity. The results were then compared with the standard and the theory. It was found that thermal comfort conditions that still utilize the movement of the wind from natural ventilation in the main waiting room of Tawang Semarang Station.

Item Type:Other
Subjects:N Fine Arts > NA Architecture
Divisions:Faculty of Engineering > Department of Architecture Engineering
Faculty of Engineering > Department of Architecture Engineering
ID Code:71550
Deposited By:INVALID USER
Deposited On:12 Apr 2019 10:22
Last Modified:16 Apr 2019 14:58

Repository Staff Only: item control page