SIMULASI OVER CURRENT RELAY MENGGUNAKAN KARAKTERISTIK STANDARD INVERSE SEBAGAI PROTEKSI BAY TRANSFORMATOR PADA GARDU INDUK 150 KV DENGAN KONFIGURASI DOUBLE BUSBAR BERBASIS ARDUINO MEGA 2560

Cahyani , Lisa Nur (2018) SIMULASI OVER CURRENT RELAY MENGGUNAKAN KARAKTERISTIK STANDARD INVERSE SEBAGAI PROTEKSI BAY TRANSFORMATOR PADA GARDU INDUK 150 KV DENGAN KONFIGURASI DOUBLE BUSBAR BERBASIS ARDUINO MEGA 2560. Undergraduate thesis, undip.

[img]
Preview
PDF (HALAMAN JUDUL)
239Kb
[img]
Preview
PDF (KATA PENGANTAR)
254Kb
[img]
Preview
PDF (DAFTAR ISI)
447Kb
[img]
Preview
PDF (ABSTRAK)
151Kb
[img]
Preview
PDF (BAB I)
131Kb
[img]
Preview
PDF (BAB II)
1873Kb
[img]PDF (BAB III)
Restricted to Repository staff only

1061Kb
[img]PDF (BAB IV)
Restricted to Repository staff only

2822Kb
[img]PDF (BAB V)
Restricted to Repository staff only

1868Kb
[img]
Preview
PDF (BAB VI)
252Kb
[img]
Preview
PDF (DAFTAR PUSTAKA)
113Kb

Abstract

ABSTRAK Dalam penyaluran listrik sangat peting adanya sistem proteksi untuk menjaga agara tenaga listrik bisa selalu disalurkan ke konsumen. Transformator merupakan peralatan penyaluran tenaga lisrik yang memiliki peranan penting sehingga sangat diperlukan adanya sistem proteksi untuk melindungi transformator tersebut dari dampak gangguan. Proteksi cadangan yang digunakan pada bay transfomator adalah Over Current Relay (OCR). Over Current Relay merupakan relai arus lebih yang akan bekerja dengan membaca input berupa besaran arus kemudian membandingkan dengan nilai setting, apabila nilai arus yang terbaca oleh relai melebihi nilai setting, maka relai akan mengirim perintah trip (lepas) kepada Pemutus Tenaga (PMT) setelah tunda waktu yang ditetapkan pada setting. Alat simulasi ini mensimulasikan prinsip kerja Over Current Relay karakteristik standard inverse pada satu fasa bay transformator Gardu Induk 150 kV dengan konfigurasi Double Busbar. Rangkaian yang digunakan adalah rangkaian catu daya sebagai sumber DC, sensor arus ACS712 sebagai pendeteksi arus, Ardunio Mega 2560 sebagai pengolah data OCR, rangkaian driver relay ULN2803 sebagai pengganti tripping coil, Relay OMRON MY2N digunakan untuk PMT pada PMT HV dan PMT LV. Rangkaian push button dan debouncer, buzzer, LED gangguan dan announciator. Lampu 12V 8Watt sebagai beban dan beberapa resistor dengan nilai tahanan berbeda-beda sebagai gangguan. Pada pengujian alat simulasi ini, ketika keadaan tidak ada gangguan, relay PMT HV dan relay PMT LV tidak bekerja sehingga masih dalam keadaan close. Ketika keadaan gangguan, dimana arus yang mengalir melebihi arus setting OCR pada alat simulasi yaitu 1,8A dan sudah memenuhi waktu tunda maka relay akan bekerja dengan membuka PMT LV karena gangguan dipasang pada sisi LV transformator. Kata kunci: Arduino Mega 2560, Simulasi OCR ABSTRACT In electricity distribution it is very important that a protection system to maintain electricity can always be channeled to consumers. The transformer is an electrical power distribution equipment that has an important role so that a protection system is needed to protect the transformer from the impact of interference. Backup protection used in bay transformer is Over Current Relay (OCR). Over Current Relay is an over current relay that will work by reading the input in the form of a current quantity and then comparing with the setting value, if the current value read by the relay exceeds the setting value, the relay will send the trip command to the Power Breaker after delay the time specified in the setting. This simulation tool simulates the working principle of Over Current Relay characteristics of an inverse standard in a single phase bay transformer 150 kV substation with Double Busbar configuration. The circuit used is a power supply circuit as a DC source, ACS712 current sensor as a current detector, Ardunio Mega 2560 as an OCR data processor, ULN2803 relay driver circuit instead of tripping coil, OMRON MY2N relay used for PMT HV PMT and LV PMT. Push button and debouncer circuit, buzzer, interference LED and announciator. 12V 8Watt lamp as a load and several resistors with different resistance values as interference. In testing this simulation tool, when there is no interference, the PMT HV relay and LV PMT relay do not work so that it is still in a closed state. When the fault condition, where the current flowing over the OCR setting current on the simulation tool is 1.8A and has already fulfilled the delay time, the relay will work by opening PMT LV because the fault is installed on the LV side of the transformer. Keywords: Arduino Mega 2560, OCR Simulation

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions:Faculty of Engineering > Diploma in Electrical Engineering
Faculty of Engineering > Diploma in Electrical Engineering
ID Code:67367
Deposited By:INVALID USER
Deposited On:30 Nov 2018 08:06
Last Modified:30 Nov 2018 08:06

Repository Staff Only: item control page