SIMULASI LOAD BREAK SWITCH THREE WAYS SEBAGAI AUTOMATIC TRANSFER SWITCH PADA JARINGAN DISTRIBUSI 20KV BERBASIS ARDUINO MEGA 2560 DENGAN TAMPILAN HUMAN MACHINE INTERFACE

NURINA, CHERLLY SARSAPARILLA DIAN (2018) SIMULASI LOAD BREAK SWITCH THREE WAYS SEBAGAI AUTOMATIC TRANSFER SWITCH PADA JARINGAN DISTRIBUSI 20KV BERBASIS ARDUINO MEGA 2560 DENGAN TAMPILAN HUMAN MACHINE INTERFACE. Undergraduate thesis, undip.

[img]PDF (LAPORAN TA)
Restricted to Repository staff only

5Mb

Abstract

ABSTRAK Proses penyaluran tenaga listrik oleh PLN tentunya dibutuhkan peralatan yang handal. Untuk mewujudkan keandalan tersebut, semua komponen penyaluran tenaga listrik harus terjaga kualitasnya. Oleh k arena itu, perlu adanya peralatan proteksi yang handal untuk memperkecil area padam ketika melakukan pemeliharaan jaringan, khususnya Jaringan Tegangan Menengah (JTM) yang sering mengalami gangguan dalam pendistribusiannya. Salah satu peralatan yang digunakan adalah load break switch three ways. Prinsip kerja load break switch three ways adalah menggunakan dua feeder yang berasal dari gardu induk tegangan 20 kV sebagai sumber utama yang menyuplai beban secara bergantian apabila salah satu penyulang mengalami padam. Load break switch three ways diatur sebagai automatic transfer switch agar memudahkan pemindahan beban dari penyulang utama ke penyulang cadangan. Arduino Mega 2560 digunakan sebagai pusat pengendali dan pengamanan terhadap ketidaknormalan arus. Arduino Mega 2560 akan membaca arus pada salah satu feeder menggunaan sensor arus ACS712. Dengan mendeteksi adanya kelebihan arus, maka akan terjadi trip pada feeder utama. Pada proses pelimpahan beban dari feeder utama ke feeder cadangan terdapat jeda waktu 2 detik. Setelah jeda waktu 2 detik, beban akan dilimpahkan pada feeder cadangan untuk mengamankan kinerja pada sistem jaringan dan menghindari terjadinya padam pada beban tersebut. Diharapkan alat simulator ini dapat memberikan pengetahuan kepada masyarakat luas tentang kinerja load break switch three ways sebagai automatic transfer switch dalam menjaga keandalan sistem distribusi tenaga listrik dengan baik dan mudah dimengerti. Kata Kunci : ACS712, Arduino Mega 2560, Arus Lebih, SCADA, Pelimpahan Beban ABSTRACT In the process of power distribution by PLN required reliable equipment. To have such reliability, the quality of all components of power distribution must be maintained. Therefore, reliable protection equipment is needed to minimize the breakdown area when there is network maintenance, especially Medium Voltage Network (JTM) which often experiences breakdown in its distribution. One of the equipment used is three ways load break switch. The working principle of the three ways load break switch is using two feeders from a 20 kV voltage substation as the main source that supplies the load alternately when one of the feeders is breakdown.. Load break switch three ways is being set as automatic transfer switch in order to help the load displacement from the main feeder to the backup feeder on the medium voltage network. The Arduino Mega 2560 will read the current on one of the feeder using the ACS712 current sensor. By detecting an overload, further attempts are made to open the switch on the main feeder. In this process, there is time delay for 2 seconds. After pass the delay, the switch on the backup feeder will be closed to secure the performance of the entire distribution and to avoid blackout at the consumer. Hopefully, this simulator project can be able to provide knowledge to the public about the working of load break switch three ways as automatic transfer switch to maintain the reliable of the power distribution system properly and easily to be understood. Keywords : ACS712, Arduino Mega 2560, Load displacement, Over Load, SCADA

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions:Faculty of Engineering > Diploma in Electrical Engineering
Faculty of Engineering > Diploma in Electrical Engineering
ID Code:67333
Deposited By:INVALID USER
Deposited On:29 Nov 2018 15:42
Last Modified:29 Nov 2018 15:42

Repository Staff Only: item control page