SIMULASI JARINGAN DISTRIBUSI PADA PREMIUM CUSTOMERS YANG DILENGKAPI DENGAN AUTOMATIC CHANGE OVER SWITCH BERBASIS ARDUINO MEGA 2560 DENGAN TAMPILAN HMI

Budi, Arief Setya (2018) SIMULASI JARINGAN DISTRIBUSI PADA PREMIUM CUSTOMERS YANG DILENGKAPI DENGAN AUTOMATIC CHANGE OVER SWITCH BERBASIS ARDUINO MEGA 2560 DENGAN TAMPILAN HMI. Undergraduate thesis, undip.

[img]
Preview
PDF (COVER)
104Kb
[img]
Preview
PDF (ABSTRAK)
13Kb
[img]
Preview
PDF (BAB I)
149Kb
[img]
Preview
PDF (BAB II)
1453Kb
[img]PDF (BAB III)
Restricted to Repository staff only

545Kb
[img]PDF (BAB IV)
Restricted to Repository staff only

1859Kb
[img]PDF (BAB V)
Restricted to Repository staff only

1159Kb
[img]
Preview
PDF (BAB VI)
158Kb
[img]
Preview
PDF (DAFTAR LAMPIRAN)
5Kb

Abstract

ABSTRAK Listrik merupakan sumber daya yang digunakan untuk menunjang kehidupan manusia. Banyaknya gangguan menyebabkan penyaluran listrik ke konsumen menjadi terputus, sehingga pelanggan akan mengalami kerugian. Bagi industri besar, kontinuitas penyaluran listrik menjadi hal yang paling utama, karena proses produksi mereka tidak terlepas dari adanya energi listrik. Untuk menjamin pasokan listrik bagi industri besar, PT. PLN (Persero) mempunyai layanan khusus yaitu layanan pelanggan premium. Sistem jaringan pada pelanggan premium terdiri dari dua penyulang yang masing-masing disuplai dari gardu induk yang berbeda. Di antara keduanya dipasang Automatic Change Over Switch yang secara otomatis dapat berpindah ke penyulang cadangan ketika penyulang utama mengalami gangguan. Tugas Akhir ini berbentuk alat simulasi yang membahas prinsip kerja dan mengklasifikasikan 4 tipe dari sistem distribusi pada pelanggan premium. Alat simulasi ini menggunakan sensor arus ACS712 sebagai input, relay LY2N 12 V sebagai output dan Arduino Mega 2560 sebagai pusat pengendali input dan output. Setting arus pada PMT sebesar 1.5 A. Beban normal berupa lampu 10W, 12 W dan 18 W serta gangguan yang diciptakan menggunakan resistor 12 Ohm. Setelah dilakukan percobaan, ketika terjadi gangguan hubung singkat arus yang dibaca sensor ACS712 sebesar 1.8 A, karena arus melebihi setting sebesar 1.5 A maka relay PMT akan trip. Relay Automatic Change Over Switch akan berpindah ke penyulang cadangan, sehingga pelanggan reguler akan padam sedangkan pelanggan premium akan tetap menyala. Ketika trafo dalam kondisi overload, yaitu beban sebesar 5 A maka pelanggan yang dipilih untuk dipadamkan terlebih dahulu adalah penyulang pada pelanggan reguler yaitu PLR5 baru kemudian penyulang pada pelanggan tipe bronze yaitu PLR1. Ketika kondisi blackout semua pelanggan akan padam kecuali pelanggan platinum dan gold karena mendapat suplai dari sistem pembangkitannya. Kata kunci: Arduino Mega 2560, Automatic Change Over Switch, Sistem Distribusi, Pelanggan Premium ABSTRACT Electricity is a resource to support human life. The number of disturbances causes the distribution of electricity to consumers to be disconnected, so the customers will experience losses. Especially for large industries, continuity of electricity distribution becomes the most important thing, because their production can not be separated from the existence of electrical energy. To ensure electricity supply for large industries, PT PLN has a special service that called premium customer service. The network system of premium customers consists of two feeder that are supplied from different substations. Among them are installed Automatic Change Over Switch which can automatically move to the backup feeder when the main feeder interrupted. This Final Project making a simulation device that will discuss the working principle and classify the differences from four types of premium customers. This simulation device used ACS712 sensor as input, relay LY2N 12 V as output and Arduino Mega 2560 to be controlling input and output system. The normal load is a 10W, 12 W and 18 W lamp and the interference is created using a 12 Ohm resistor. The result of the experiment is, when a short circuit occurs the current read by the ACS712 sensor is 1.8 A, because the current exceeds the setting of 1.5 A then the PMT relay will trip. Automatic Relay Change Over Switch will move to the backup feeder, so that regular customers will be extinguished while premium customers will remain on. When the transformer is overloaded, which is a load of 5 A, the customer selected to be extinguished first is a feeder for regula r customers (PLR5), then feeder on bronze customers (PLR1). When blackout conditions, all customers will be extinguished except for platinum and gold customers because they get supplies from the generation system Keywords : Arduino Mega 2560, Automatic Change Over Switch, Distribution System, Premium Customers.

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions:Faculty of Engineering > Diploma in Electrical Engineering
Faculty of Engineering > Diploma in Electrical Engineering
ID Code:67180
Deposited By:INVALID USER
Deposited On:28 Nov 2018 08:29
Last Modified:28 Nov 2018 08:34

Repository Staff Only: item control page