KOORDINASI RECLOSER DAN SSO FUNGSI VIT UNTUK OPTIMALISASI JARINGAN DISTRIBUSI BERBASIS ARDUINO MEGA 2560 MENGGUNAKAN SCADA

Triatmaja, Wisnu Prawira (2018) KOORDINASI RECLOSER DAN SSO FUNGSI VIT UNTUK OPTIMALISASI JARINGAN DISTRIBUSI BERBASIS ARDUINO MEGA 2560 MENGGUNAKAN SCADA. Undergraduate thesis, undip.

[img]
Preview
PDF (COVER)
207Kb
[img]
Preview
PDF (KATA PENGANTAR)
254Kb
[img]
Preview
PDF (DAFTAR ISI)
273Kb
[img]
Preview
PDF (ABSTRAK)
151Kb
[img]
Preview
PDF (BAB I DAN II)
2097Kb
[img]PDF (BAB III)
Restricted to Repository staff only

143Kb
[img]PDF (BAB IV)
Restricted to Repository staff only

1152Kb
[img]PDF (BAB V)
Restricted to Repository staff only

1087Kb
[img]
Preview
PDF (BAB VI)
256Kb
[img]
Preview
PDF (DAFTAR PUSTAKA)
162Kb

Abstract

ABSTRAK Panjangnya jaringan untuk pendistribusian tenaga listrik menimbulkan terjadinya gangguan seperti gangguan alam, hewan, sistem dan lain sebagainya. Disamping itu, Listrik harus terjamin kontinuitasnya untuk menunjang kegiatan perekonomian, pendidikan, dan seluruh aktifitas manusia. Oleh karena itu, penggunaan dan pengembangan alat proteksi dilakukan untuk memastikan keamanan pada sistem dan mempersempit daerah padam. Peralatan proteksi pada proses pendistribusian tenaga listrik diantaranya recloser, SSO, FCO dan relay proteksi. Peralatan proteksi tersebut harus tercipta koordinasi antar peralatan proteksi untuk bekerja dalam satu sistem jaringan distribusi. Salah satu contoh koordinasi yang digunakan dalam pendistribusian tenaga listrik yaitu koordinasi antara recloser dan SSO. Pada Alat Simulasi Tugas Akhir ini, recloser akan open ketika arus melebihi 1,7 Ampere dengan waktu open 2000 ms dan akan close kembali setelah 2000 ms dari kondisi open. Sedangkan SSO fungsi VIT akan open ketika arus melebihi 1,3 Ampere dan tegangan kurang dari 1,0 Volt dengan waktu 1000 ms. Koordinasi recloser dan SSO pada Tugas Akhir ini akan bekerja ketika recloser merasakan arus sebesar 1,7 Ampere dan SSO merasakan arus sebesar 1,3 Ampere. Recloser adalah peralatan pertama yang open dalam waktu 2000 ms setelah merasakan gangguan. Ketika recloser open, maka tegangan pada SSO akan bernilai 0 Volt dan SSO akan open dalam waktu 1000 ms setelah syarat arus dan gangguan terpenuhi. Kemudian recloser akan close kembali setelah 2000 ms dari kondisi open. Dengan menggunakan Arduino Mega 2560 sebagai pusat pengendali, koordinasi antara SSO dan recloser dapat berjalan dengan membaca arus yang dideteksi oleh ACS712, membaca tegangan dari rangkaian sensor tegangan, kontrol relay, dan menghubungkan dengan aplikasi SCADA. SCADA pada jaringan distribusi tenaga listrik digunakan untuk controlling keypoint serta monitoring arus dan tegangan dari jarak jauh secara real time. Kata kunci : Arduino Mega 2560, Koordinasi recloser dan SSO, SCADA ABSTRACT The length of the network for the distribution of electricity causes disturbances such as natural disturbances, animals, systems and so forth. In addition, Electricity must be ensured continuity to support economic activities, education, and all human activities. Therefore, the use and development of protective devices is carried out to ensure system security and narrow down the outages. Protective equipment in the process of distributing electric power such as recloser, SSO, FCO and protection relay. Such protection equipment must be created coordination between protection equipment to work in one network distribution system. One example of the coordination used in the distribution of electricity is the coordination between recloser and SSO. In this Final Simulation Tool, the recloser will open when the current exceeds 1.7 Ampere with an open time of 2000 ms and will close again after 2000 ms from open condition. In this Final Simulation Tool, SSO VIT function will open when the current exceeds 1.3 Ampere and voltage less than 1.0 Volt with time 1000 ms. The coordination of the recloser and SSO in this Final Project will work when the recloser senses a current of 1.7 Ampere and the SSO senses a current of 1.3 Ampere. Recloser is the first equipment open in 2000 ms after feeling the disturbance. When the recloser is open, the voltage on the SSO will be 0 Volt and SSO will open within 1000 ms after the current and interruption conditions are met. Then the recloser will close again after 2000 ms from open condition. Using the Arduino Mega 2560 as the controlling center, the coordination between SSO and recloser can read the current detected by ACS712, read the voltage from the voltage sensor circuit, control the relay, and connect the SCADA application. SCADA on the power distribution network is used for keypoint controlling and remote current and voltage monitoring in real time. Keywords: Arduino Mega 2560, Coordination of recloser and SSO, SCADA.

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions:Faculty of Engineering > Diploma in Electrical Engineering
Faculty of Engineering > Diploma in Electrical Engineering
ID Code:67151
Deposited By:INVALID USER
Deposited On:27 Nov 2018 14:13
Last Modified:27 Nov 2018 14:13

Repository Staff Only: item control page