FAUZIYAH , AYU RISMA (2018) SIMULASI PERANCANGAN SISTEM DETEKSI KEBAKARAN DAN SISTEM SPRINKLER MENGGUNAKAN SENSOR ASAP DAN SENSOR SUHU BERBASIS PROGRAMMABLE LOGIC CONTROLLER (PLC) SCHNEIDER TM221CE16R DAN HUMAN MACHINE INTERFACE (HMI) PADA SMARTHOME. Undergraduate thesis, undip.
| PDF (COVER DLL) 2880Kb | |
| PDF (BAB I) 263Kb | |
| PDF (BAB II) 1193Kb | |
PDF (BAB III) Restricted to Repository staff only 851Kb | ||
PDF (BAB IV) Restricted to Repository staff only 1852Kb | ||
PDF (BAB V) Restricted to Repository staff only 563Kb | ||
| PDF (BAB VI) 122Kb | |
| PDF (DAFTAR PUSTAKA) 262Kb |
Abstract
ABSTRAK Kemajuan teknologi saat ini menuntut hampir semua alat-alat keperluan seharihari tidak terlepas dari kebutuhan listrik, mulai dari alat -alat kerja sampai perabotan rumah tangga. Kondisi ini mengakibatkan rentan sekali terjadi kebakaran pada rumah. Salah satu indikasi terjadinya suatu kebakaran pada rumah ditandai dengan adanya asap dan perubahan suhu pada ruangan. Perubahan suhu ruangan yang berubah dan dapat memicu kebakaran adalah sebesar >45ºC. Untuk mengetahui kepekatan asap dan perubahan suhu pada ruangan maka digunakan sensor. Sensor merupakan sebuah komponen penting yang digunakan untuk mendeteksi suatu besaran fisik menjadi besaran listrik sehingga dapat dianalisa dengan rangkaian listrik tertentu. Pada Tugas Akhir ini penyusun menggunakan sensor asap MQ-2 dan sensor suhu LM35 sebagai indikator terjadinya kebakaran. Sensor asap dan sensor suhu berfungsi untuk mengubah besaran konsentrasi asap dan suhu menjadi besaran-besaran listrik yang kemudian dihubungkan pada Programmable Logic Controller (PLC) sebagai prosessor sistem. Dalam sistem ini inputan dari sensor asap dan sensor suhu akan diolah menjadi bentuk sinyal dan akan menghasilkan keluaran dari sensor asap berupa buzzer dan kipas. Kipas berfungsi sebagai penghisap asap yang terdapat pada ruangan, saat ruangan sudah bersih dari adanya asap maka otomatis buzzer dan kipas akan mati. Sedangkan apabila asap terlalu pekat dan mengakibatkan suhu di ruangan berubah menjadi >47ºC, maka PLC akan memproses inputan sensor suhu dan akan memberika n keluaran berupa pompa air dan springkler sebagai upaya pemadam kebakaran pada rumah secara dini. Kata kunci: Sensor Asap, Sensor Suhu, PLC, Pompa Air, Kipas, xix ABSTRACT Current technological advances demand that almost all of the daily necessities are inseparable from electricity needs, ranging from work tools to household furniture. This condition results in the vulnerability of a house fire. One indication of a fire at home is marked by smoke and temperature changes in the room. Changes in room temperature that change and can trigger a fire is> 45ºC. To determine the density of smoke and changes in temperature in the room, sensors are used. The sensor is an important component that is used to detect a physical quantity into an electrical quantity so that it can be analyzed with certain electrical circuits. In this Final Project the compiler uses MQ-2 smoke sensor and LM35 temperature sensor as an indicator of fire. Smoke sensor and temperature sensor function to change the amount of smoke and temperature concentration into electrical quantities which are then connected to the Programmable Logic Controller (PLC) as a system processor. In this system input from the smoke sensor and temperature sensor will be processed into a signal form and will produce output from the smoke sensor in the form of buzzer and fan. The fan functions as a smoke absorber in the room, when the room is clean from smoke, the buzzer and fan will automatically die. Whereas if the smoke is too thick and causes the temperature in the room to change to> 47ºC, the PLC will process the input of the temperature sensor and will provide output in the form of a water pump and sprinkler as an effort to fire the house early. Keywords: Smoke Sensor, Temperature Sensor, PLC, Water Pump, Fan
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Faculty of Engineering > Diploma in Electrical Engineering Faculty of Engineering > Diploma in Electrical Engineering |
ID Code: | 67031 |
Deposited By: | INVALID USER |
Deposited On: | 23 Nov 2018 16:12 |
Last Modified: | 23 Nov 2018 16:12 |
Repository Staff Only: item control page