ANALISIS KEBISINGAN DI AREA LUAR GEDUNG KULIAH TEKNIK MESIN UNIVERSITAS DIPONEGORO BERDASARKAN PEMETAAN INTENSITAS KEBISINGAN DENGAN MENGGUNAKAN SOFTWARE SURFER

Wulandari,Meidha Yana, Meidha (2017) ANALISIS KEBISINGAN DI AREA LUAR GEDUNG KULIAH TEKNIK MESIN UNIVERSITAS DIPONEGORO BERDASARKAN PEMETAAN INTENSITAS KEBISINGAN DENGAN MENGGUNAKAN SOFTWARE SURFER. Undergraduate thesis, Universitas Diponegoro.

[img]
Preview
PDF
147Kb

Abstract

Sekolah atau institusi pendidikan merupakan suatu tempat dimana berlangsungnya proses belajar mengajar. Salah satu faktor untuk mencapai kondisi lingkungan belajar yang baik adalah terhindar dari masalah kebisingan. Dimana institusi pendidikan atau sekolah yang diteliti adalah Universitas Diponegoro Jurusan Teknik Mesin.. Penelitian ini dilakukan dengan cara mengukur tingkat kebisingan menggunakan Sound Level Meter dengan mengambil 6 titik lokasi yang tersebar di bagian luar gedung. Dari hasil pengukuran kebisingan dibuatkan pemetaan kebisingan agar diketahui peta sebaran kebisingan di area tersebut. Menyebarkan kuesioner sebanyak 300 responden agar diketahui tingkat penerimaan kebisingan yang dirasakan oleh mahasiswa. Baku mutu tingkat kebisingan yang diperbolehkan dalam sekolah atau institusi pendidikan adalah 55 dB menurut Keputusan Menteri Negara Lingkungan Hidup No. 48 Tahun 1996. Hasil penelitian,beberapa titik sampel telah melebihi standar baku tingkat kebisingan. pada hari Selasa yang paling tinggi memiliki nilai sebesar 61.64 dB(A) yang berada pada titik 2 dan nilai terendahnya berada pada titik 4 dengan nilai sebesar 51.45 dB(A). Sementara pada hari Rabu nilai tertinggi berada pada titik 5 dengan nilai sebesar 68.26 dB(A) dan nilai terendah berada pada titik 6 dengan nilai 47.45 dB(A). Untuk pengukuran hari Kamis, nilai tertinggi LSM berada pada titik 2 dengan 62.17 dB(A) dan nilai terendah sebesar 47.55 dB(A) yang berada pada titik 6. Pada pemetaan, nilai maksimum pengukuran yang dilakukan pada hari Selasa memiliki nilai sebesar 61.64 dBA yang ditunjukan oleh warna oranye yang semakin terlihat jelas. Dan nilai terendah pada pengukuran hari Selasa memiliki nilai sebesar 51.45 dBA yang ditunjukkan dengan warna kuning yang terang. Untuk hari Rabu,nilai maksimum pengukuran yang dilakukan pada hari Rabu memiliki nilai sebesar 68.26 dBA yang ditunjukan oleh warna kuning yang semakin terlihat jelas. Dan nilai terendah pengukuran adalah sebesar 47.75 dBA. Sementara hasil pemetaan untuk hari Kamis, nilai maksimum pengukuran yang dilakukan memiliki nilai sebesar 62.17 dBA yang ditunjukan oleh warna merah yang semakin terlihat jelas. Dan nilai terendah pengukuran adalah sebesar 47.55 dBA. Persepsi mahasiswa terhadap tingkat kebisingan lingkungan sebanyak 72.30 % menjawab bahwa di area Jurusan Teknik Mesin Undip cukup bising,15.40% sangat bising, dan 12.30 % tidak bising. Dari persepsi tersebut mahasiswa beranggapan bahwa 62.30% terganggu dengan kebisingan yang timbul. Sebanyak 16.20% menjawab sangat terganggu dan 21.50% merasa tidak terganggu. Gangguan tersebut pallng banyak menyebabkan gangguan pendengaran atau ketidaknyaman dalam mendengar sebanyak 90.80%. Kata kunci : : Kebisingan, Software Surfer, Profil Kebisingan, Peta Kontur. Abstract [Analysis Of Noise In The Outside Of Area Of Engineering Technique Understanding Machine University Of Diponegoro Based On Mapping Of Intensity Using Sofware Surfer]. School or educational institution is a place where the learning process begin. One of the factors to achieve a good learning environment condition is to avoid noise problem. This research took place at Diponegoro University Department of Mechanical Engineering.The purpose of this research was to know the profile of noise,the relation between high noise levels and level of comfort, other than that this research want to know the nosie level of the areas . The noise was measured with Sound Level Meter and was taken at six areas. Measurement was done in busy days in 24 hours. The measurement repeated as many as three. After the measurement done, the result can be visualized by Software surfer. This research vis conducted by measuring the noise level using Sound Level Meter (SLM) by taking 6 point locations spread in the outside building. From the measurement of noise,noise mapping was done to know the noise distribution map .. Then spread the questionnaire as much as 300 respondents to know the level of acceptance of noise perceived by the students. The standard of permissible noise level rating for schools or educational institutions is 55 dB according to the Decree of the State Minister of the Environment. 48 of 1996. From the research results, some sample points have exceeded the standard noise level. On Tuesday's measurements the points that exceeded the standard noise level include point 2 of 61.64 dBA and point 3 of 56.94 dBA. For Wednesdays, the points beyond the standard noise level are point 2 of 58.23 dBA and point 5 of 68.27 dBA. On Thursday's measurements the points that exceeded the noise level standard were point 2 with 62.17 dBA and point 3 of 56.98 dBA. On Mapping, the maximum value will be shown by increasingly visible colors. On Tuesday mapping the maximum value is indicated by an orange color with a value of 61.64 dBA. On Wednesday the maximum value shown by the yellow color is increasingly visible degan nili of 68.26 dBA. For Thursday mapping, the maximum value of measurement is marked with a more visible red color with a value of 62.17 dBA. While the perception of students to the level of environmental noise as much as 72.30% answered that the area of Mechanical Engineering Department is quite noisy with 62.30% of students are disturbed by the noise that arises. The area that the students think has a high noise level is the Canteen area with a percentage of 45%. Of these results as many as 90.80% of students feel disturbed comfort in terms of hearing or interfere with hearing and communication disruption. Key Words : Noise, Software Surfer, The Profile Of Noise, Contour Maps

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TD Environmental technology. Sanitary engineering
Divisions:Faculty of Engineering > Department of Environmental Engineering
Faculty of Engineering > Department of Environmental Engineering
ID Code:58846
Deposited By:INVALID USER
Deposited On:03 Jan 2018 19:10
Last Modified:03 Jan 2018 19:10

Repository Staff Only: item control page