UJI ALAT DINAMIKA PROSES ORDE DUA NON INTERACTING DILENGKAPI SENSOR LAJU ALIR AIR DENGAN BUKAAN VALVE 1/5, 1/2, DAN 3/5 (Performance Test Of Second Order Non Interacting Dynamic Process Equipped By Water Flow Sensor With Manipulated Variable 1/5, 1/2, and 3/5)

ERIN, CITRA DESIANA (2017) UJI ALAT DINAMIKA PROSES ORDE DUA NON INTERACTING DILENGKAPI SENSOR LAJU ALIR AIR DENGAN BUKAAN VALVE 1/5, 1/2, DAN 3/5 (Performance Test Of Second Order Non Interacting Dynamic Process Equipped By Water Flow Sensor With Manipulated Variable 1/5, 1/2, and 3/5). Undergraduate thesis, undip.

[img]
Preview
PDF (COVER) - Published Version
29Kb
[img]
Preview
PDF (ABSTRAK) - Published Version
87Kb
[img]
Preview
PDF (KATA PENGANTAR) - Published Version
184Kb
[img]
Preview
PDF (DAFTAR ISI) - Published Version
100Kb
[img]
Preview
PDF (BAB I) - Published Version
89Kb
[img]
Preview
PDF (BAB II) - Published Version
1018Kb
[img]
Preview
PDF (BAB III) - Published Version
89Kb
[img]
Preview
PDF (BAB IV) - Published Version
230Kb
[img]
Preview
PDF (BAB V) - Published Version
227Kb
[img]PDF (BAB VI) - Published Version
Restricted to Repository staff only

436Kb
[img]
Preview
PDF (BAB VII) - Published Version
90Kb
[img]
Preview
PDF (DAFTAR PUSTAKA) - Published Version
87Kb

Abstract

Second order process is a combination from two processes of first order where in the second order non interacting dynamic process height level in both tanks does not influence each other. It called non interacting when height level in the second tank will not affect the out flow rate of the first tank. Experiment with 1/5 water level valve opening reached the second steady state in height 10.2 cm for the 1st tank and 7.2 cm for the 2nd tank in 250 seconds as well as a steady of water flow rate in 3 for both sensor (1st, 2nd and 3rd sensor), whereas the opening of valve 1/2 flow rate water reached a steady state on both sensor is 3 with height level water 14.5 cm for the 1st tank and 10.4 for 2nd tank in time 300 second and on 3/5 water level valve opening reached a steady state in 270 second at height level of 10.1 cm for the 1st tank and 6.3 cm for 2nd tank as well as flow rate reached 4 for 1st sensor and for 2nd sensor and 3rd sensor reached a flow rate 3. Keywords : Second Order Process, non-interacting, flow rate, height level

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TP Chemical technology
Divisions:Faculty of Engineering > Diploma in Chemical Engineering
Faculty of Engineering > Diploma in Chemical Engineering
ID Code:58356
Deposited By:INVALID USER
Deposited On:13 Dec 2017 14:54
Last Modified:13 Dec 2017 14:54

Repository Staff Only: item control page