MAULANA, TITOK LIMAS (2016) Analisa Kadar Salinitas dan Fe2+ (Ferro) terhadap Kualitas Air Sumur Kecamatan Tembalang sebagai Sumber Air Minum ( Analysis of Salinity and Fe2+ Concentration ( Ferro ) Against Quality Well Water District Tembalang as Drinking water Source ). Undergraduate thesis, UNDIP.
| PDF (COVER) - Published Version 40Kb | |
| PDF (DAFTAR ISI) - Published Version 145Kb | |
| PDF (KATA PENGANTAR) - Published Version 56Kb | |
| PDF (BAB I) - Published Version 100Kb | |
| PDF (ABSTRAK) - Published Version 9Kb | |
| PDF (BAB II) - Published Version 260Kb | |
| PDF (BAB III) - Published Version 133Kb | |
| PDF (BAB IV) - Published Version 189Kb | |
| PDF (BAB V) - Published Version 115Kb | |
PDF (BAB VI) - Published Version Restricted to Repository staff only 264Kb | ||
| PDF (BAB VII) - Published Version 133Kb | |
| PDF (DAFTAR PUSTAKA) - Published Version 152Kb | |
| PDF (DAFTAR GAMBAR) - Published Version 129Kb | |
| PDF (DAFTAR TABEL) - Published Version 136Kb | |
| PDF (LAMPIRAN) - Published Version 542Kb |
Abstract
Refractometer is an instrument used to measure the level / concentration of dissolved materials. Eg sugar, salt, protein. The working principle of a refractometer as the name suggests is utilizing the refraction of light, in which the material to be tested salinity dropped on blue prism and close the day light plate after the reading scale plate legible. The method used to analyze the content of Fe2+ is permanganometry, namely by way of titrated using KmnO4 solution and sample the atmosphere is made acidic by adding H2SO4 and titration temperature of 65 °C. Raw materials used in this lab is the well water with added District Tembalang H2SO4. Salinity and Fe2+ concentration is found in various water sources, namely the absence of color and odor in the water. In this study was observed three variables: the ratio of the time differences in sampling. Generate salinity levels 0 and Fe2+ 0.0112 mg / L. Things that affect the results of the lab is the contamination of KmnO4 by light, can lead to less rigorous determination of Fe2+ in the sample. Keywords: refractometer, permanganometry, water wells
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | T Technology > TP Chemical technology |
Divisions: | Faculty of Engineering > Diploma in Chemical Engineering Faculty of Engineering > Diploma in Chemical Engineering |
ID Code: | 53384 |
Deposited By: | INVALID USER |
Deposited On: | 28 Apr 2017 15:59 |
Last Modified: | 28 Apr 2017 15:59 |
Repository Staff Only: item control page