RANCANG BANGUN TEST BED SISTEM KOMPRESOR TORAK DUA TINGKAT ( DESIGN AND TEST BED PISTON COMPRESSOR SYSTEM LEVEL TWO )

Murliansyah, Brian Dwi and Handayani, Sri Utami and Sutrisno, Sutrisno (2016) RANCANG BANGUN TEST BED SISTEM KOMPRESOR TORAK DUA TINGKAT ( DESIGN AND TEST BED PISTON COMPRESSOR SYSTEM LEVEL TWO ). Undergraduate thesis, D3 Teknik Mesin Fakultas Teknik.

[img]
Preview
PDF
61Kb
[img]
Preview
PDF
22Kb
[img]
Preview
PDF
346Kb
[img]PDF
Restricted to Repository staff only

284Kb
[img]PDF
Restricted to Repository staff only

311Kb
[img]
Preview
PDF
15Kb

Abstract

Test bed sistem kompresor torak dua tingkat ini merupakan suatu peralatan yang digunakan untuk mempelajari kinerja kompresor torak 2 tingkat. Proses pembuatan test bed kompresor torak dua tingkat meliputi beberapa tahapan, yaitu : pertama desain test bed kompresor torak dua tingkat, kedua proses fabrikasi yang meliputi pembuatan rangka, perakitan instrumen alat ukur dan komponen kompresor. Kemudian melakukan pengujian komponen supaya pada saat test bed dijalankan dapat memperoleh hasil yang baik dan maksimal. Hasil yang diperoleh dari pengujian test bed kompresor torak dua tingkat yaitu daya adiabatik maksimal 1,69 HP, daya listrik maksimal yang terpakai sebesar 1,72 HP, temperatur maksimal yang tercapai pada tekanan 12 bar sebesar 172 °C, efisiensi energi maksimal yang dihasilkan sebesar 70,65%. Kata kunci : termometer, daya adiabatik, daya listrik, efisiensi energi Test bed system design of two stages reciprocating compressor is an equipment which is used to learn about performance two stages reciprocating compresor. Test bed two stages reciprocating compressor manufacturing is consist of several steps. First is designing of test bed two stages reciprocating compressor. The second is fabricating process consist of measurement instrument and compressor's component. Subsequently, testing proccess to ensure and guarantee to the components are able to do well and maximum performance. The results of bed compressor test are 1.69 HP of adiabatic maximum power, 1.72 HP of maximum utilized power of electricity, the maximum temperature which could be reached on 12 bars is 172 degree celcius, and the maximum efficiency of energy is 70,65 percent which could be produced. Keywords: thermometer, adiabatic power, power of electricity, efficiency of energy

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Faculty of Engineering > Diploma in Mechanical Engineering
Faculty of Engineering > Diploma in Mechanical Engineering
ID Code:49821
Deposited By:INVALID USER
Deposited On:19 Aug 2016 09:12
Last Modified:19 Aug 2016 09:12

Repository Staff Only: item control page