UJI ALAT DINAMIKA PROSES ORDE DUA INTERACTING CAPACITIES DENGAN BUKAAN VALVE 25%, 12,5%, dan 6,25% (Test Tool of The Dynamic Process of Second Order Capacities Interacting with Openings Valve 25%, 12,5% and 6,25%)

HANIFAH, HANIFAH (2015) UJI ALAT DINAMIKA PROSES ORDE DUA INTERACTING CAPACITIES DENGAN BUKAAN VALVE 25%, 12,5%, dan 6,25% (Test Tool of The Dynamic Process of Second Order Capacities Interacting with Openings Valve 25%, 12,5% and 6,25%). Undergraduate thesis, Undip.

[img]
Preview
PDF (COVER, HAL PENGESAHAN, ABSTRAK, KATA PENGANTAR, DAFTAR ISI) - Published Version
517Kb
[img]
Preview
PDF (BAB I) - Published Version
84Kb
[img]
Preview
PDF (BAB II) - Published Version
386Kb
[img]
Preview
PDF (BAB III) - Published Version
130Kb
[img]
Preview
PDF (BAB IV) - Published Version
106Kb
[img]PDF (BAB V) - Published Version
Restricted to Repository staff only

271Kb
[img]PDF (BAB VI) - Published Version
Restricted to Repository staff only

759Kb
[img]PDF (BAB VII) - Published Version
Restricted to Repository staff only

123Kb
[img]
Preview
PDF (DAFTAR PUSTAKA) - Published Version
80Kb
[img]
Preview
PDF (LAMPIRAN) - Published Version
117Kb

Abstract

Process control is a combination of work tools automatic control. Many parameters have to be controlled in a process. Among them is the pressure (pressure), flow (flow), temperature (temperature), especially in the field of chemical engineering. On the order of two interacting process-level capacities in both the tank height will affect the flow coming out of the tank. From the graph the results of the experiment shows that the water level will reach a new equilibrium despite the flow of input changed suddenly. In the experiment with the valve 25% water level reaches steady state (5 cm) new with a height of 11.7 cm and 11.5 cm A tank on the tank B in 25 minutes, while the valve openings 12.5% water achieve steady state (8.5 cm) new with a height of 16 cm in the tank A and 15.8 cm in the tank B within 30 minutes and to the valve of 6.25% water level reaches steady state (6.1 cm ) new with a height of 9.1 cm in the tank A and 9.0 cm in the tank and takes 20 minutes. Factors affecting this process dynamics testing tool is fluid pressure setting, the valve settings and accuracy in reading the scale height of the fluid level. Keywords : Process Control , Process Dynamics , Process Order Two Interacting

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TP Chemical technology
Divisions:Faculty of Engineering > Diploma in Chemical Engineering
Faculty of Engineering > Diploma in Chemical Engineering
ID Code:47944
Deposited By:INVALID USER
Deposited On:15 Mar 2016 10:13
Last Modified:15 Mar 2016 10:13

Repository Staff Only: item control page