EVALUASI PERFORMA TURBIN UAP UNIT 1 PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR DENGAN METODE HEAT RATE ( PERFORMANCE EVALUATION OF STEAM TURBINE UNIT 1 PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR WITH HEAT RATE METHOD )

Gusti, Amrisyah Pahlevi Setya and Setyoko, Bambang (2015) EVALUASI PERFORMA TURBIN UAP UNIT 1 PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR DENGAN METODE HEAT RATE ( PERFORMANCE EVALUATION OF STEAM TURBINE UNIT 1 PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR WITH HEAT RATE METHOD ). Undergraduate thesis, D3 Kerjasama PT. PLN - FT UNDIP Bidang Teknik Mesin.

[img]
Preview
PDF
63Kb
[img]
Preview
PDF
20Kb
[img]
Preview
PDF
197Kb
[img]PDF
Restricted to Repository staff only

505Kb
[img]PDF
Restricted to Repository staff only

230Kb
[img]
Preview
PDF
13Kb

Abstract

Turbin uap jika digunakan terus menerus, maka keandalan dan umur pakainya akan semakin berkurang. Hal ini akan berdampak pada menurunnya efisiensi pembangkit dan akhirnya akan menyebabkan biaya operasional yang semakin tinggi. Oleh sebab itu, penulis tertarik untuk mengetahui kinerja pembangkit dengan mengevaluasi performa turbin uap di PLTU 3 Jawa Timur Tanjung Awar-Awar dengan metode heat rate dan efisiensi termal. Dengan dilakukannya perhitungan ini akan didapatkan nilai mengenai ada tidaknya penurunan performa turbin PLTU 3 Jawa Timur Tanjug Awar-Awar. Heat rate adalah konsumsi panas yang digunakan untuk membangkitkan energi listrik sebesar satu kWh. Heat rate turbin uap dapat dihitung dengan perbandingan antara panas yang diberikan boiler dengan listrik yang dihasilkan generator. Sedangkan efisiensi termal dapat dihitung dengan perbandingan antara listrik yang keluar dari generator dengan panas yang diberikan boiler. Hasil perhitungan heat rate ketika comissioning dan setelah unit beroperasi selama 15 bulan (10800 jam operasi) menunjukkan trend heat rate yang cenderung naik sesuai dengan persamaan y = 0,001x + 8570,2. Kenaikan heat rate ini menunjukkan penurunan efisiensi termal turbin uap dan dari grafik efisiensi termal didapatkan persamaan y = -0,00003x + 39,81505. Hasil evaluasi heat rate dan efisiensi termal turbin uap setelah 15 bulan beroperasi tidak menunjukkan perbedaan yang besar, sehingga dapat dikatakan unit masih dalam kondisi yang baik. Kata kunci : turbin, heat rate, efisiensi termal Steam turbines if used continuously, the reliability and lifetime will be reduced. This will decrease the plant efficiency and ultimately will lead to higher operating costs. Therefore, the authors are interested to know the performance of plants by evaluating the performance of the steam turbines in the power plant 3 East Java Tanjung Awar-Awar with methods of heat rate and thermal efficiency. By doing this calculation will be obtained values regarding whether there is a decrease in performance turbine power plant in East Java Tanjug 3 Awar-Awar. Heat rate is the heat consumption used to generate electrical energy by the kWh. Steam turbine heat rate can be calculated by the ratio between the heat supplied by the boiler with electricity generated by generator. While the thermal efficiency can be calculated by the ratio between the electricity coming out of the generator with the heat given by boiler. Heat rate calculation results when commissioning and after the unit operation for 15 months (10800 running hours) showed a trend heat rate which tends to rise in accordance with the equation y = 0,001x + 8570.2. The increase in heat rate showed a decrease in thermal efficiency of the steam turbine and the thermal efficiency is obtained from the graph the equation y = -0,00003x + 39.81505. Results of evaluation of heat rate and thermal efficiency steam turbines after 15 months of operation showed no big difference, so we can say the unit is still in good condition. Keyword : turbine, heat rate, thermal efficiency

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Faculty of Engineering > Diploma in Mechanical Engineering
Faculty of Engineering > Diploma in Mechanical Engineering
ID Code:47772
Deposited By:INVALID USER
Deposited On:02 Mar 2016 11:47
Last Modified:02 Mar 2016 11:47

Repository Staff Only: item control page