Rahmat, Rahmat and Senen, Senen (1999) EKSPERIMEN MODEL UJI KAVITASI POMPA SENTRIFUGAL. TEKNIK, Tahun XIX Edisi 2 . pp. 93-100. ISSN 0852-1697
| PDF 1549Kb |
Abstract
The aim for this research is getting a real description about plan result of setting up plans and the model experiment of the model cavitation centrifugal pump. In this research a centrifugal pump repaired in a test model cavitation that accept the treatment on suction side. The treatment on suction side in the form of abstruction fluida flow make use of stop faucet until reached of cavitation. The phase to research this cavitation started from the pressure on suction side minus 5 cmHg. From the result of test we get that cavitation happened of the moment pressure reached of minus 69 cmHg. With followed the signes happened of cavitation like situation of high vibration.
Item Type: | Article |
---|---|
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Faculty of Engineering > Diploma in Mechanical Engineering Faculty of Engineering > Diploma in Mechanical Engineering |
ID Code: | 39549 |
Deposited By: | INVALID USER |
Deposited On: | 19 Jul 2013 09:06 |
Last Modified: | 19 Jul 2013 09:06 |
Repository Staff Only: item control page