PERHITUNGAN BEBAN PENDINGINAN , PEMILIHAN DAN PEMASANGAN AIR CONDITIONING DI RUANG AUTOCAD PSD III TEKNIK MESIN FAKULTAS TEKNIK UNIVERSITAS DIPONEGORO SEMARANG COOLING LOAD CALCULATIONS, SELECTION AND INSTALLATION OF AIR CONDITIONING IN ROOM III PSD AUTOCAD MECHANICAL ENGINEERING FACULTY OF ENGINEERING, UNIVERSITY OF SEMARANG DIPONEGORO

Handayani, Sri Utami and Afendi , Achmad Arif and Fuadi, Muh. Jamil and Sonhaji , Muhammad (2012) PERHITUNGAN BEBAN PENDINGINAN , PEMILIHAN DAN PEMASANGAN AIR CONDITIONING DI RUANG AUTOCAD PSD III TEKNIK MESIN FAKULTAS TEKNIK UNIVERSITAS DIPONEGORO SEMARANG COOLING LOAD CALCULATIONS, SELECTION AND INSTALLATION OF AIR CONDITIONING IN ROOM III PSD AUTOCAD MECHANICAL ENGINEERING FACULTY OF ENGINEERING, UNIVERSITY OF SEMARANG DIPONEGORO. Undergraduate thesis, Fakultas Teknik.

[img]
Preview
PDF
523Kb

Abstract

Indonesia merupakan negara beriklim tropis yang terdiri dari musim hujan dan musim panas, pada saat musim panas suhu ruangan tinggi sehingga penghuni tidak nyaman. Untuk menciptakan kondisi yang nyaman maka perlu dipasang pendingin ruangan (AC). Pada tugas akhir ini penulis merencanakan perhitungan beban pendinginan pada ruang autocad, unit AC yang digunakan adalah jenis AC Split. Untuk dapat menghasilkan udara dengan kondisi yang diinginkan, maka peralatan yang dipasang harus mempunyai kapasitas yang sesuai dengan beban pendinginan yang dimiliki ruangan tersebut. Untuk itu diperlukan survey dan perhitungan untuk menentukan beban pendinginan. Proses perencanaan perhitungan beban pendinginan dimulai dengan merencanakan suhu udara didalam ruang autocad. Dengan desain suhu 25 oC dan RH 55% didapatkan hasil perhitungan beban pendinginan total (GTH) sebesar 49237,09 Btu/hr dan temperatur udara suplai ( sebesar 53 ºF. Sehingga pada ruang autocad harus dipasang 4 unit AC, tetapi pada ruang autocad hanya terpasang 1 unit AC dengan daya 1,5 PK sehingga suhu yang dihasilkan kurang maksimal. Indonesia is a tropical country consisting of the rainy season and summer, during the summer high temperature of the room so that the occupants uncomfortable. To create favorable conditions it is necessary to set air-conditioning (AC). In this thesis the author plans on the space cooling load calculation sautocad, air-conditioning unitused is the type of AC Split. To be able to produce the desired air conditions, the equipment installed musthave the appropriate capacity of which is owned by the cooling load of the room. It required surveys and calculations to determine the cooling load. The planning process starts with the cooling load calculation of air temperature within the space planning autocad. With a design temperature of 25°C and RH 55% obtained the total cooling load calculation (GTH) of 49237,09 Btu/hr and the supply air temperature (t_sa) of 53 ºF. So that the chamber should be installed 4 autocad air conditioning unit, but the space just installed autocad 1 AC unit with the 1.5 PK so that the resulting temperature less than the maximum.

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Faculty of Engineering > Diploma in Mechanical Engineering
Faculty of Engineering > Diploma in Mechanical Engineering
ID Code:35960
Deposited By:INVALID USER
Deposited On:03 Aug 2012 08:02
Last Modified:03 Aug 2012 08:02