MODIFIKASI INSTALASI PENGUJIAN PADA JET PUMP ( MODIFICATION OF THE JET PUMP INSTALLATION TESTING )

Wildan, Akhirul and Dirgantara, Angga Bagus and Sholachudin, Muhammad and Sutomo, Sutomo (2011) MODIFIKASI INSTALASI PENGUJIAN PADA JET PUMP ( MODIFICATION OF THE JET PUMP INSTALLATION TESTING ). Undergraduate thesis, Fakultas Teknik.

[img]
Preview
PDF
524Kb

Abstract

Tujuan pelaksanaan tugas akhir ini adalah mengetahui karakteristik dan fenomena gelembung aira yang ada di pipa out put dengan cara pengaturan katup di setiap pipa. Bahan kerja adalah air biasa. Setelah itu katup di jaga pada bukaan (stroke) 90 derajat dan putaran pompa diatur menggunakan inverter pada frekuensi 30 Hz dinaikan hingga 50 Hz dengan selang 5 Hz. Variabel dalam percobaan ini adalah frekuensi motor listrik (analog putaran pompa) dan bukaan katup. Putaran (motor listrik dan pompa), debit (input dan output), tekanan (input dan out put). Hasil percobaan yang diperoleh adalah : 1) gelembung air pada pipa output hilang pada penutupan katup 60 derajat di katup 3 frekuensi 50 Hz. 2) Pada pengaturan katup 1 dan 2 ternyata tidak begitu berpengaruh pada gelembung di pipa output. Disamping itu juga membedakan pembacaan tekanan dan mengkalibrasi yang dipasang pada satu titik yang terletak pada pipa tekan. Selain itu juga menganalisa pertambahan kavitasi pada suhu air 30o dengan suhu air 40o. Air dipanasi menggunakan 2 heater sekiranya suhu di jaga agar tetap konstan. Kemudian yang terakhir membandingkan 6 resistan yang terdapat pada pipa tekan dengan pengaturan katup tekan ditutup 30o dengan frekuensi 50 Hz. Resistan meliputi : melingkar (1 putaran), belokan 90o (1 putaran), belokan 180o (1 putaran), melingkar (3 putaran), belokan 90o ( 3 putaran), dan belokan 180o ( 3 putaran). The aim of this thesis is to determine the characteristics and phenomena that exist in aira bubble pipe output by setting the valves on each pipe. Work material is ordinary water. After that the valve on guard at the opening (stroke) 90 degrees and turns the pump is set using an inverter at a frequency of 30 Hz to 50 Hz increased with the lapse of 5 Hz. The variables in this experiment is the frequency of the electric motor (pump rotation analog) and the valve opening. Rotation (electric motor and pump), discharge (input and output), pressure (input and output). The experimental results obtained are: 1) water bubbles on the pipe the output lost by closing the valve 60 degrees in the valve 3 a frequency of 50 Hz. 2) In setting the valves 1 and 2 were not so influential on the bubble in the pipeline output. It also distinguishes calibrate pressure readings and mounted on a single point located on the pipe tap. It also analyzes the increase of cavitation on water temperature water temperature of 30oC to 40oC. Water is heated using a second heater if the temperature keep it constant. Then the last one to compare 6-resistant pipe found on the press with press closed valve settings 30oC with a frequency of 50 Hz. Resistance include: circular (1 lap), 90o bends (1 lap), turn 180o (1 lap), circular (3 rounds), 90o bends (3 rounds), and turn 180o (3 rounds).

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Faculty of Engineering > Diploma in Mechanical Engineering
Faculty of Engineering > Diploma in Mechanical Engineering
ID Code:32787
Deposited By:INVALID USER
Deposited On:02 Feb 2012 09:13
Last Modified:02 Feb 2012 09:13

Repository Staff Only: item control page