Interferensi Fe 3++ terhadap Adsorbsi Cu2++ pada spektrofotometri serapan atom

Sumartono , Jantung (2005) Interferensi Fe 3++ terhadap Adsorbsi Cu2++ pada spektrofotometri serapan atom. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

1063Kb
[img]
Preview
PDF
16Kb
[img]
Preview
PDF
354Kb
[img]
Preview
PDF
439Kb
[img]
Preview
PDF
348Kb
[img]
Preview
PDF
480Kb
[img]
Preview
PDF
341Kb
[img]PDF
Restricted to Repository staff only

424Kb
[img]
Preview
PDF
320Kb
[img]
Preview
PDF
329Kb
[img]
Preview
PDF
387Kb

Abstract

Penelitian ini didasarkan pada kasus pencucian Printed Circuit Board (PCB). Limbah pencucian PCB merupakan limbah yang mengandung ion tembaga dan besi yang berbahaya bagi makhluk hidup. Analisis dan Cu2+ dengan Spektrofotometri Serapan Atom dapat terganggu oleh adanya Fe3+ sehingga hasil absorbansi Cu dan. Cu2+ menjadi tidak akurat. Lanttan yang mengandung ion tembaga dan besi perlu dilakukan analisis Cu+ dan Cu2+ dengan Spektrofotometri Serapan Atom untuk mendapatkan pengaruh interferensi Fe3+ terhadap absorbansi Cu+ dan Cu2+. Pembuatan larutan dan Cu2+ 5 ppm ditambah dengan variasi konsentrasi Fe3+, kemudian diukur absorbansinya dengan Spektrofotometri Serapan Atom pada A, = 324,7 tun. Variasi konsentrasi Fe3+ dimaksudkan untuk mendapatkan pengaruh interferensi Fe3+ terhadap absorbansi dan Cu2+ dengan Spektrofotometri Serapan Atom. Hasil yang didapatkan dari penelitian adalah absorbansi Cu+ dan Cu2+ semakin menurun sebanding dengan peningkatan konsentrasi Fe3+. Hasil tersebut menunjukkan baliwa 7 = 324,7 tun kurang memberikan serapan maksimum untuk analisis k-uantitatif Cu+ maupun Cu2+ dalam campuran Cu dan Fe3+ serta Cu2+ dan Fe3+ pada Spektrofotometri Serapan Atom. This research relied on the case of Printed Circuit Board (PCB) washing. Waste of PCB washing contains copper and iron ions that dangerous for human being. The presence of Fe3+ interference cause Cu and Cu2+ absorbance measurements are not accurate. Solution containing copper and iron ions need to be analyzed its Cu and Cu24 content by Atomic Absorption Spectrophotometly to get the influence of Fe interference on Cu and Cu2 absorbance. Solutions of Cu+ and Cu24 5 ppm were prepared with various Few concentration, then their absorbance were measured by Atomic Absorption Spectrophotometry on A = 324,7 nm. Variation of Fe34 concentration was used to get the influence of Fe interference on analysis of Cu and Cu2+ with Atomic Absorption .Spectrophotometry. It was concluded that the Cu{ and Cu24 absorbance had tendency to decrease with increasing of Fe concentration. The result showed that = 324,7 tun gave less optimum absorbance for quantitative analysis of Cu and'Cu2+ the presence of Fe'4by Atomic Absorption Spectrophotometry,

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QD Chemistry
Divisions:Faculty of Science and Mathematics > Department of Chemistry
ID Code:31073
Deposited By:Mr UPT Perpus 1
Deposited On:14 Nov 2011 11:00
Last Modified:14 Nov 2011 11:00

Repository Staff Only: item control page