Studi pemisahan Crd+ dan Cr2072- dalam air memakai kronotografi penukar ion.

Subiyantoro, Subiyantoro (1997) Studi pemisahan Crd+ dan Cr2072- dalam air memakai kronotografi penukar ion. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

1531Kb
[img]
Preview
PDF
15Kb
[img]
Preview
PDF
356Kb
[img]
Preview
PDF
464Kb
[img]
Preview
PDF
388Kb
[img]
Preview
PDF
637Kb
[img]
Preview
PDF
507Kb
[img]PDF
Restricted to Repository staff only

476Kb
[img]
Preview
PDF
329Kb
[img]
Preview
PDF
349Kb
[img]
Preview
PDF
388Kb

Abstract

Telah dilakukan pemisahan krom (III) sebagai ion Cr!-/- dan krom (VI) sebagai ion Cr20 dalam air memakai kromatografi penukar ion jenis Amberlite IRA 400 (bentuk C1) ukuran 20 - 40 mesh. Campuran 10 ml krom (III) 30 ppm dan 10 ml krom (VI) 30 ml dilewatkan melalui kolom yang berisi resin Amberlite IRA 400 dengan diameter dan tinggi kolom adalah 1,4 cm dan 18 cm. Akuabides digunakan untuk mengelusi krom (III) dan larutan natrium hidroksida untuk mengelusi krom (VI) dengan konsentrasi dan laju alir yang berVariasi. Eluat dianalisa dengan SSA untuk krom (III) pada panjang gelombang 358,5 nm dan dengan spektrofotometri uv-vis untuk krom (VI) pada panjang gelombang 371 nm. Hasil penelitian menunjukkan bahwa krom (III) dapat dipisahkan dari krom (VI). Dan proses elusi krom (VI) dengan eluen NaOH tergantung pada konsentrasi dan laju alir eluen yang digunakan. Hasil. yang paling baik untuk kecepatan alir dan konsentrasi eluen adalah pada 6 ml/menit dengan NaOH 3 N. Having been separated thE Chromium (III) as Crs+ ion and the Chromium (VI) as Cr207 ion in water by the use of chromatography-anion exchange type Amberlite IRA 400 (C1 form ) size of 20 - 40 mesh. The mixtures of 30 ppm Chromium (III) 10 ml and 30 ppm Chromium (VI) 10 ml were passed through the column containing Amberlite IRA 400 resin with column diameter and high were 1,4 cm .and 18 cm. The aquabidest was used for elution of Chromium (III) and sodium hydroxide solution was used for elution of Chromium (VI) by variation of flow .rate and concentation. The eluate was detected by AAS for Chromium (III) at wavelenght of 358,5 nm and by uv-visible Spectrofotometry method for Chromium (VI) at wavelenght of 371 nm. The research showed that Chromium (III) was separated from Chromium (VI). And the elution of Chromium (VI) used sodium hydroxide solution as eluent depending on concentration and flow rate of eluent used.The optimum product for flow rate and eluent concentration were 6 mi/minutes for the former and 3 N NaOH solution for the latter..

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QD Chemistry
Divisions:Faculty of Science and Mathematics > Department of Chemistry
ID Code:30643
Deposited By:Mr UPT Perpus 1
Deposited On:04 Nov 2011 08:27
Last Modified:04 Nov 2011 08:27

Repository Staff Only: item control page