Kajian analisa kolorimetri untuk mengukur kandungan besi dalam air tanah.

Santoso , Heru Bowo (1994) Kajian analisa kolorimetri untuk mengukur kandungan besi dalam air tanah. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

1973Kb
[img]
Preview
PDF
15Kb
[img]
Preview
PDF
348Kb
[img]
Preview
PDF
464Kb
[img]
Preview
PDF
372Kb
[img]
Preview
PDF
860Kb
[img]
Preview
PDF
557Kb
[img]PDF
Restricted to Repository staff only

454Kb
[img]
Preview
PDF
333Kb
[img]
Preview
PDF
333Kb
[img]
Preview
PDF
754Kb

Abstract

Telah dilakukan penelitian penentuan kadar besi .dalam air tanah dengan metode kolorimetri. Kolorimeter yang digunakan basil rekayasa penyusunan fotokonduktif dan komponen - komponen elektronik sederhana lainnya. Dengan prinsip, bila suatu larutan dikenai cahaya monokromatik, ada .intensitas cahaya yang diserap dan yang diteruskan. Intensitas cahaya yang diteruskan.akan ditangkap detektor dan akan mengubah arus listrik pada detektor yang besarnya dapat dibaca pada penuniuk. Besi yang ad dibuat kompleks dengan thiosianat menladi [Fe(SON)6 yang berwarna merah. Pengukuran dilakukan dengan mengubah ubah jarak detektor dengan kuvet/cuplikan untuk mendapatkan kepekaan dan ketelitian yang paling balk. Untuk perbandingan dilakukan juga pengukuran dengan Spektronik-20. Akibatnya basil yang diperoleh dipengaruhi oleh kemampuan alat dan iuga perilaku analisa. Hasil penelitian menunjukkan bahwa kadar besi dalam air tanah di Fakultas MIPA Undip adalah 6533 ppb, diukur dengan alat hasil rekayasa dan 6133 ppb diukur dengan Spektronik-20. The iron concentration in soil water have been measured with colorimetry method. Colorimeter that was used fotoconductive and electronic components combined modification. The principle was if some solution illuminated by monocromatic lamplight. The intensity of light and transfered. The light intensity that is transfered would be detected by using a detector and the changes of electric current could be read at display. Iron cFmplexed with Thiocyanat become red color rFe(SCN)6j . To get a good respons and accuracy measurement was done by the changes of detector and cuvet distance. For _comparison was done by measurement with spectronic-20. The result depended on instrument accuracy and analysis behaviour. The result of observation indicated that iron concentration at Faculty of MIPA, Diponegoro University 6533 ppb, measured with modification instrument and 6133 ppb with spectronic-20. This ;document is Undip Institutional Repository Collection. The author(s) or copyright o wn er(s) agree that UNDIP-I 1V subnilission to any medium or format for

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QD Chemistry
Divisions:Faculty of Science and Mathematics > Department of Chemistry
ID Code:30574
Deposited By:Mr UPT Perpus 1
Deposited On:02 Nov 2011 15:41
Last Modified:02 Nov 2011 15:41

Repository Staff Only: item control page