Pengaruh perubahan Rasio GRID LINEAR terhadap pengurangan Radiasi Hambur

Sisharyanto , Sisharyanto (2001) Pengaruh perubahan Rasio GRID LINEAR terhadap pengurangan Radiasi Hambur. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

2844Kb
[img]
Preview
PDF
17Kb
[img]
Preview
PDF
360Kb
[img]
Preview
PDF
563Kb
[img]
Preview
PDF
444Kb
[img]
Preview
PDF
1055Kb
[img]
Preview
PDF
526Kb
[img]PDF
Restricted to Repository staff only

703Kb
[img]
Preview
PDF
363Kb
[img]
Preview
PDF
336Kb
[img]
Preview
PDF
851Kb

Abstract

Telah dilakukan penelitian pengendalian radiasi hambur dengan menggunakan grid yang berbeda rasio pada rentang tenaga sinar-X rad iodi agnostik. Penelitian dilakukan dengan menggunakan grid linear yang berbeda rasio terdiri dari rasio 5:1, 6:1, 8:1, 10:1, dan 12:1. Obyek penyinaran berupa phantom air dalam wadah berukuran 42,5 cm X 30 cm X 20,5 cm dengan ketinggian air mencapai 20 cm. Faktor paparan yang digunakan adalah variasi tegangan tabung dari 50 kV sampai dengan 110 kV dengan interval kenaikan 10 kV, arus tabung dan waktu penyinaran 50 mAS, serta jarak fokus ke film adalah 100 cm. Penyinaran dilakukan dengan tanpa grid terlebih dahulu dan hasilnya dibandingkan dengan penyinaran menggunakan grid linear sesuai dengan rasionya untuk diketahui tingkat kenaikan kontrasnya. Hasil penelitian menunjukkan bahwa pemakaian grid dapat mengurangi radiasi hambur yang mencapai film sehingga kontras radiograf yang dihasilkan meningkat. Semakin tinggi rasio grid yang digunakan akan didapatkan nilai kontras maksimum untuk tegangan tabung tertentu. Pada penyinaran tanpa grid kontras maksimum dicapai pada tegangan tabung 60 kV dengan nilai 0,35, dan setelah dilakukan penyinaran dengan grid maka didapatkan kontras yang meningkat pada tegangan tabung 80 kV-110 kV. It has been doing a research about the checking scatter radiation with uses a grid which different ratio for radio diagnostic X-ray energy range. This experiment was used linear of grid which different ratio are 5:1, 6:1, 8:1, 10:1, and 12:1. The object of water phantom on the place with 42,5 cm X 30 cm X 20,5 cm and with water high to 20 cm. The tube voltage are value from 50 kV to 110 kV with interval increase of 10 kV, 50 mAs and focus to film distance 100 cm. A shine has been doing without grid before result have different. A shine with linear grid suitable with ratio to knows of increase contrast. The result of research shows uses a grid can decrease scatter radiation until film so contrast radiographic have be resulted the increase. The higher the grid ratio so the higher contrast for the tube voltage given. For the exposure without the grid, the higher contrast at the tube voltage 60 kV with value 0,35, and after the exposure with the grid then the result of increase contrast at the tube voltage 80 kV —110 kV. J I j 1.1- MJ...J-1,-J.1.0 J,Jp11.1...61. xv _It's/ agree -ma[JNL111 submission to any medium or format for the purpose of preservation. The author(s) or coviright owner(s) also agree that J.UU11-' may Keep mare (Joe wiry oi Uu submission for purposes of security, back-up and preservation. ( http://eprints.undip.ac.id)

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QC Physics
Divisions:Faculty of Science and Mathematics > Department of Physics
ID Code:30518
Deposited By:Mr UPT Perpus 1
Deposited On:01 Nov 2011 13:07
Last Modified:01 Nov 2011 13:07

Repository Staff Only: item control page