Pengaruh Massa JenisBahan dan Tebal Irisan (Slice) terhadap CT Number pada citra Computed Tomography

Bawono, Surindro (2000) Pengaruh Massa JenisBahan dan Tebal Irisan (Slice) terhadap CT Number pada citra Computed Tomography. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

2409Kb
[img]
Preview
PDF
17Kb
[img]
Preview
PDF
358Kb
[img]
Preview
PDF
521Kb
[img]
Preview
PDF
481Kb
[img]
Preview
PDF
918Kb
[img]
Preview
PDF
538Kb
[img]PDF
Restricted to Repository staff only

698Kb
[img]
Preview
PDF
358Kb
[img]
Preview
PDF
339Kb
[img]
Preview
PDF
556Kb

Abstract

Telah dilakukan penelitian pengaruh massa jenis bahan dan tebal irisan (slice) terhadap nilai CT Number. Penelitian pengaruh massa jenis dan tegangan tabung sinar-X terhadap CT Number menggunakan 7 jenis bahan yang memiliki massa jenis berbeda, sedang tegangan tabung sinar-X yang digunakan yaitu 110 kV dan 130 kV. Penelitian pengaruh tebal irisan terhadap CT Number menggunakan bahan kayu sebagai obyek satu jenis bahan dan bahan berlapis, dengan tebal irisan scanning yang digunakan yaitu 2 rnm, 5 mm dan 10 mm. Hasil percobaan menunjukan grafik CT Number sebagai fungsi massa jenis mendekati linier, dimana semakin besar massa jenis akan menyebabkan CT 1\himber semakin besar, sedang pada tegangan tabung yang lebih tinggi maka rentang perubahan nilai CT Number sebagai akibat dari massa jenis semakin menurun. Perbedaan tebal irisan scanning untuk satu jenis bahan tidal( mempengaruhi nilai CT Number yang dihasilkan, tebal irisan scanning hanya menentukan seberapa tebal daerah yang terscanning., sedang untuk bahan berlapis tebal irisan mempengaruhi nilai CT Aizmber. A research concerning about the effect of density and the slice thickness to the CT Number has been done. Within the research of density and x-ray tube voltage effect, it was used 7 material types having different density and the x-ray tube voltage that were selected are 110 kV and 130 kV, meanwhile the research concerning about the effect of scanning slice thickness to the CT Number, it was utilised a wooden material as a material type with the scanning slice thickness of 2 mm, 5 mm, and 10 mm. The experiment results show that the graphic of the CT Number as function of density approximates linearly in which the increased density will lead to the increased CT Number, meanwhile, for the higher tube voltage alteration extent of the CT Number values due to the density therefore was getting more decreased. The scanning slice thickness doesn't affect the resulted CT Number values. The scanning slice thickness only determines the thickness of the seemed area for a material type, while for a layered material the scanning slice thickness affects the CT Number. right owner(s) agree submission to any medium „, XiV or copyright owner(s) also agree submission for purpose' ',curl )ck-up and presel .ac.id)

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QC Physics
Divisions:Faculty of Science and Mathematics > Department of Physics
ID Code:30481
Deposited By:Mr UPT Perpus 1
Deposited On:31 Oct 2011 13:56
Last Modified:31 Oct 2011 13:56

Repository Staff Only: item control page