Ssetiawan , Andi (2000) Model Fisis Tomografi Antar Lubang (Crosswell) Metoda Geofisika Elektromagnetik dengan Pemrograman Borland Delphi 1.0. Undergraduate thesis, FMIPA UNDIP.
PDF Restricted to Repository staff only 3370Kb | ||
| PDF 17Kb | |
| PDF 368Kb | |
| PDF 487Kb | |
| PDF 409Kb | |
| PDF 591Kb | |
| PDF 525Kb | |
PDF Restricted to Repository staff only 612Kb | ||
| PDF 349Kb | |
| PDF 341Kb | |
| PDF 2040Kb |
Abstract
Telah dilakukan penelitian permodelan fisis struktur geologi 3 lapisan pada bak kaca tikuran 60 x 60 x 150 cm3, menggunakan 2 lubang bar (Crosswell) metoda geofisika elelctromagnetik dengan pemrograman Borland Delphi 1.0. Pengukuran pada tegangan amplitudo rata-rata dilakukan di 3 titik tembak pada kedalaman 5 cm, 20 cm, 35 cm. Alat penelitian menggunakan pemancar berfrelatensi 7 MHz/6 W, kalibrasi peralatan diperoleh dari konduktivitas udara lembab di laboratorium (kelembaban 80%, suhu 200 C). Pengambilan data menggunakan satu medium tanpa anomali dan 9 model anomali yang divariasi letaknya Metoda/kerangka yang digunakan -adalah menghitung tegangan amplitudo rata-rata sesuai kedalaman pemancar-penerima (9 lintasan) untuk mendapatkan nilai atenuasi, konduktivitas dan resistivitas (interpretasi kuantitatif). Interpretasi kualitatif dilakukan dengan pemrograman Delphi 1.0 yang mentinjukkan citra resistivitas 3 lapisan medium sebagai fungsi gradasi warns dan kedalaman. Basil permodelan fisis tomografi yang diperoleh adalah nilai resistivitas masing-masing kedalaman sesuai dengan jenis lapisannya dan dibandingkan dengan literatur (hasil interpretaSi kuantitatif). Selanjutnya dan nilai resisitivitas masing-masing lintasan sesuai kedalaman dicitrakan dengan pemrograman Delphi 1.0 yang menunjukkan citra 3 lapisan medium tanpa anomali dan 9 citra medium dengan variasi letak anomali (basil interpretasi kualitatif). Physical modelling of geological structure had been carried out by using electromagnetic tomography method. The model is arranged by three layers of medium with in 60 x 60 x 150 cm3 dimention of glass box. Borland Delphi 1.0 is used to view imeges of medium, and anomalous by three shoot-receiver depth points in 5 cm, 20 cm and 35 cm. 7 MHz/6 W was used and calibrated on air conductivity in the laboratory wich had humidity 80% and temperature 20°C. The Data were taken from a normal medium and nine variations of anomalous medium. In this method, the average amplitudes had been calculated quantitatively according to the depth of transmitter-receiver (9 paths) to obtained the values of attenuation, conductivity and resisitivity. Quantitative interpretation was carried out by Delphi 1.0 programming wich the images of three layer of medium shown as fUnction of colour gradation and depth. In these model, it had been obtained resistivity values in each depth appropriate the tipe of layer, and then were compared by literatures (product of quantitative interpretation). Then resistivity values in each paths appropriate of depth arid images of layer as resistivity function by Borland Delphi 1.0 programming showed three layers image a norm al medium and nine variations anomalous medium (product of qualitative interpretation)..
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Science and Mathematics > Department of Physics |
ID Code: | 30472 |
Deposited By: | Mr UPT Perpus 1 |
Deposited On: | 31 Oct 2011 13:10 |
Last Modified: | 31 Oct 2011 13:10 |
Repository Staff Only: item control page