Susanto , Edy (1999) Analisis penggunaan Ultrasonik Dpler pada pengukuran kecepatan Relatif Aliran Darah. Undergraduate thesis, FMIPA UNDIP.
PDF Restricted to Repository staff only 3780Kb | ||
| PDF 19Kb | |
| PDF 358Kb | |
| PDF 615Kb | |
| PDF 443Kb | |
| PDF 850Kb | |
| PDF 642Kb | |
PDF Restricted to Repository staff only 638Kb | ||
| PDF 351Kb | |
| PDF 380Kb | |
| PDF 1855Kb |
Abstract
Telah dilakukan penelitian tentang pengukuran parameter pulsatility index (PI) dan mean velocity (vm) melalui pemeriksaan ultrasonik Doppler terhadap obyek aorta abdominalis dari manusia sehat guna mendapatkan nilai normal P1 dan vm, serta menganalisa pengaruh penyudutan probe. Penelitian dilakukan dengan variasi penyudutan probe dan variasi obyek. Setelah dilakukan kompilaSi maka data yang digunakan sebagai panduan operasional hanya yang memiliki prosentase kesalahan sudut estimasi kurang dari 10%. Hasil penelitian menunjukkan bahwa : (1) Semakin besar penyudutan probe, semakin besar pula nilai velocity yang terukur. Velocity secara nil adalah pada penyudutan probe mil derajat; (2) Batas penyudutan probe untuk mendapatkan prosentase kesalahan sudut estimasi 2,5° kurang dari 10% adalah sampai dengan penyudutan 62,50; (3) Pada aorta abdominalis nilai normal PI adalah 2-3 dan nilai normal vn; adalah 20-22 cm/detik; (4) Frekuensi Doppler tidak dipengaruhi oleh penyudutan probe. Kata kunci : Ultrasonik Doppler, pulsatility index dan mean velocity. Study on the measurement of pulsatility index (P1) and mean velocity (v.) parameters have been done by Doppler ultrasonic examination at abdominal aorta in the health body to find out 'not only the normal value of Pi and v. but also the effect of probe angles. The study is conducted by the probe angle and object variations. The data is compiled. The data whose error of estimation angle less than 10% are used to arranged an operational manual. Result show that : (1) The larger angle of the probe, the' value of the velocity will larger too. Real velocity happen if the angle of the probe is zero; (2) To obtain percentage estimated angle 2,5° less than 10%, the probe angle must below 62,50; (3) On the abdominal aorta the normal value P1 is 2-3 and v. is 20- 22cm/sec; (4) Doppler frequency is not effected by probe angles. • Key words Doppler ultrasonic, pulsatility index and mean velocity.
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Science and Mathematics > Department of Physics |
ID Code: | 30451 |
Deposited By: | Mr UPT Perpus 1 |
Deposited On: | 31 Oct 2011 09:24 |
Last Modified: | 31 Oct 2011 09:24 |