Pengaruh variasi Tegangan dan Arus terhadap kualitas Radiograf dan dosis yang diterima pasien pada pemotretan paru-paru proyeksi "Postero Anterior" (Studi kasus di RSPAD Gatot Subroto Jakarta)

W a s e s o , W a s e s o (1998) Pengaruh variasi Tegangan dan Arus terhadap kualitas Radiograf dan dosis yang diterima pasien pada pemotretan paru-paru proyeksi "Postero Anterior" (Studi kasus di RSPAD Gatot Subroto Jakarta). Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

3104Kb
[img]
Preview
PDF
25Kb
[img]
Preview
PDF
351Kb
[img]
Preview
PDF
546Kb
[img]
Preview
PDF
383Kb
[img]
Preview
PDF
797Kb
[img]
Preview
PDF
443Kb
[img]PDF
Restricted to Repository staff only

728Kb
[img]
Preview
PDF
331Kb
[img]
Preview
PDF
339Kb
[img]
Preview
PDF
1116Kb

Abstract

Penelitian bertujuan untthk memperoleh nilai faktor eksposi dalam rangka penerapan tegangan tinggi yang berguna bagi penekanan dosis radiasi pasien pada pemotretan patu-pam proyeksi postero anterior. Penelitian dilakukan di Departemen Radiologi RSPAD "l3atot Soebroto" Jakarta dengan menggunakan obyek pasien dengan indikasi foto paru-paru, menggunakan pesawat sinar-X SIREGRAPH Type A.90. Penelitian dilakukan pada tegangan 70 kV, 8 mAs yang secara umum dikeljakan dengan pesawat sinar-X. Perubahan faktor eksposi dilakukan dengan memvariasi tegangan dan arus sehingga akan didapatkan suatu faktor eksposi yang hasil gambar fotonya akan sama, bahkan lebih baik dari hasil gambar foto Röntgen semula tetapi dosis radiasi yang diterima pasien akan lebih rendah dari faktor eksposi mula-mula. Kata Dosis radiasi pasien, kV, mAs. The purpose of this experiment is t© obtain the value of the exposure factor in case of high voltage implementation that used in lowering the patient's radiation dose in the lungs imaging using poster° anterior projection. The experiment was done at the Radiologic Department RSPAD "Gatot Soebroto" Jakarta using patient as the object with lungs photo indication, by mean of SIRE GRAPH X-ray. The exposure factor was obtained by increasing the voltage in kV order) and lowering the current (in mA order), so we obtained the exposure factor which have the image quality as good as even better than previous Röntgen image, except the radiation dose accepted by the patient is lower than the previous exposure factors. Key words: The patient's radiation dose, kV, mAs.

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QC Physics
Divisions:Faculty of Science and Mathematics > Department of Physics
ID Code:30427
Deposited By:Mr UPT Perpus 1
Deposited On:31 Oct 2011 07:36
Last Modified:31 Oct 2011 07:36

Repository Staff Only: item control page