Suradiyo , Agung (1997) Simulasi analisa pengaktifan neutron cepat dengan menggunakan program komputer Bahasa Turbo Pascal. Undergraduate thesis, FMIPA UNDIP.
PDF Restricted to Repository staff only 5Mb | ||
| PDF 16Kb | |
| PDF 350Kb | |
| PDF 465Kb | |
| PDF 389Kb | |
| PDF 848Kb | |
| PDF 728Kb | |
PDF Restricted to Repository staff only 836Kb | ||
| PDF 352Kb | |
| PDF 349Kb | |
| PDF 4095Kb |
Abstract
Analisa Pengaktifan Neutron Cepat 14 MeV mempunyai potensi yang sangat besar untuk slat analisa unsur. Terlebih lagi dengan adanya generator neutron yang mampu menghasilkan fluks neutron sampai dengan 1012 nlcm2.dt. clan sistem transfer pneumatik khusus yang disebut sistem rabbit (rabbit system). Program Analisa Pengaktifan Neutron Cepat menggunakan Bahasa pemrograman Turbo Pascal telah disusun guna memudahkan para pemakai generator neutron untuk mendapatkan data-data nuklir dari berbagai isotop dan untuk perhitungan yang berhubungan dengan metode Analisa Pengaktifan Neutron Cepat. Perhitungan tersebut antara lain perhitungan konsentrassi, pehitungan tampang lintang reaksi, perhitungan fluks neutron, perhitungan batas deteksi dan perhitungan efisiensi detektor. Sensitivitas analitik dari masing-masing unsur telah dihitung. Dalam simulasi sensitivitas analitik rnemmjuldcan bahwa jika fluk neutron yang dipergunakan semakin besar maka sensitivitas analitik dari masing-masing unsur akan mengecil. 14 MeV fast neutron activation analisys has been a high potential for element analyse requirement, Even there is neutron generator which has capable in producing neutron flux as much 1012 n/cm2.s and transfer pneumatik program especially called rabbit system used. Turbo Pascal language program has been arranged in order to fasilitate generator users and then they can get nuclear data from various isotop and for calculating with is conected by fast neutron activation analyse method. These calculation are concentrate calculation, cross section calculation, neutron flux calculation, detection limit calculation and calculation of detector efficency. Sensitivity of analityc from each element has been calculated. In sensitivity of analityc simulation shows that if neutron flux is used higher, sensitivity of analityc from each element will decrease.
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Science and Mathematics > Department of Physics |
ID Code: | 30367 |
Deposited By: | Mr UPT Perpus 1 |
Deposited On: | 28 Oct 2011 07:09 |
Last Modified: | 28 Oct 2011 07:09 |
Repository Staff Only: item control page