Pengaruh penggunaan Grid linier grid fokus terhadap kualitas radiograf

Ikhwan S , Muhammad (2002) Pengaruh penggunaan Grid linier grid fokus terhadap kualitas radiograf. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

1981Kb
[img]
Preview
PDF
16Kb
[img]
Preview
PDF
351Kb
[img]
Preview
PDF
500Kb
[img]
Preview
PDF
417Kb
[img]
Preview
PDF
1023Kb
[img]
Preview
PDF
464Kb
[img]PDF
Restricted to Repository staff only

477Kb
[img]
Preview
PDF
334Kb
[img]
Preview
PDF
350Kb
[img]
Preview
PDF
426Kb

Abstract

Telah dilakukan penelitian mengenai pengaruh penggunaan grid linear dan grid fokus terhadap kualitas radiograf. Penelitian dilakukan dengan menggunakan grid linear dan grid fokus dengan berbagai rasio terdiri dari jenis linear rasio 5:1 dan rasio 6:1, jenis fokus rasio 5:1 dan rasio 6:1 serta tanpa grid. Penyinaran dilakukan terhadap phantom dengan faktor paparan yang dipergunakan adalah tegangan tabung 60 kV, arus tabung 200 mA dan waktu penyinaran (s) 0,02 detik serta jarak fokus ke film 100 cm. Analisa dilakukan dengan membandingkan kontras radiograf antara grid linear dan grid fokus pada rasio yang sama serta tanpa grid. Hasil penelitian menunjukkan bahwa penggunaan grid fokus mempunyai kualitas lebih unggul dibanding grid linear, hal tersebut dapat dilihat dan rentang kontras yang dihasilkan oleh grid fokus yaitu pada rasio 5:1 antara 0,03 sampai 0,10, rasio 6:1 rentang kontras 0,04 sampai 0,11 sedangkan pada grid linear rentang kontras yang dihasilkan untuk rasio 5:1 yaitu 0,02 sampai 0,07 dan rasio 6:1 rentang kontras antara 0,03 sampai 0,09, adapun rentang kontras untuk non grid yaitu 0,01 sampai 0,05. It has been done the study of the feature of usage the linear and focus grid type to the radiograph quality. The study use various ratio of linear and focus grid type such as the linear and focus type with ratio 5:1 and 6:1 and without grid. The phantom irradiation use the exposure factor: tube voltage 60 kV, tube current 200mA, irradiation time (s) 0,02 seconds and distance from focus to film 100 cm. The analysis has been done by comparing the radiograf contras between the linear and focus grid in same ratio and without grid. The result of research shown that usage of focus grid has higher quality than linear grid, shown by contras extend that made by focus grid with ratio 5:1 between 0,03 to 0,10, ratio 6:1 between 0,04 to 0,11 where as the contras extend in linear grid with ratio 5:1 between 0,02 to 0,07 and ratio 6:1 between 0,03 to 0,09 and contras extend for without grid between 0,01 to 0,05.

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QC Physics
Divisions:Faculty of Science and Mathematics > Department of Physics
ID Code:30341
Deposited By:Mr UPT Perpus 1
Deposited On:27 Oct 2011 13:06
Last Modified:27 Oct 2011 13:06

Repository Staff Only: item control page