Ikhwan S , Muhammad (2002) Pengaruh penggunaan Grid linier grid fokus terhadap kualitas radiograf. Undergraduate thesis, FMIPA UNDIP.
PDF Restricted to Repository staff only 1981Kb | ||
| PDF 16Kb | |
| PDF 351Kb | |
| PDF 500Kb | |
| PDF 417Kb | |
| PDF 1023Kb | |
| PDF 464Kb | |
PDF Restricted to Repository staff only 477Kb | ||
| PDF 334Kb | |
| PDF 350Kb | |
| PDF 426Kb |
Abstract
Telah dilakukan penelitian mengenai pengaruh penggunaan grid linear dan grid fokus terhadap kualitas radiograf. Penelitian dilakukan dengan menggunakan grid linear dan grid fokus dengan berbagai rasio terdiri dari jenis linear rasio 5:1 dan rasio 6:1, jenis fokus rasio 5:1 dan rasio 6:1 serta tanpa grid. Penyinaran dilakukan terhadap phantom dengan faktor paparan yang dipergunakan adalah tegangan tabung 60 kV, arus tabung 200 mA dan waktu penyinaran (s) 0,02 detik serta jarak fokus ke film 100 cm. Analisa dilakukan dengan membandingkan kontras radiograf antara grid linear dan grid fokus pada rasio yang sama serta tanpa grid. Hasil penelitian menunjukkan bahwa penggunaan grid fokus mempunyai kualitas lebih unggul dibanding grid linear, hal tersebut dapat dilihat dan rentang kontras yang dihasilkan oleh grid fokus yaitu pada rasio 5:1 antara 0,03 sampai 0,10, rasio 6:1 rentang kontras 0,04 sampai 0,11 sedangkan pada grid linear rentang kontras yang dihasilkan untuk rasio 5:1 yaitu 0,02 sampai 0,07 dan rasio 6:1 rentang kontras antara 0,03 sampai 0,09, adapun rentang kontras untuk non grid yaitu 0,01 sampai 0,05. It has been done the study of the feature of usage the linear and focus grid type to the radiograph quality. The study use various ratio of linear and focus grid type such as the linear and focus type with ratio 5:1 and 6:1 and without grid. The phantom irradiation use the exposure factor: tube voltage 60 kV, tube current 200mA, irradiation time (s) 0,02 seconds and distance from focus to film 100 cm. The analysis has been done by comparing the radiograf contras between the linear and focus grid in same ratio and without grid. The result of research shown that usage of focus grid has higher quality than linear grid, shown by contras extend that made by focus grid with ratio 5:1 between 0,03 to 0,10, ratio 6:1 between 0,04 to 0,11 where as the contras extend in linear grid with ratio 5:1 between 0,02 to 0,07 and ratio 6:1 between 0,03 to 0,09 and contras extend for without grid between 0,01 to 0,05.
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Science and Mathematics > Department of Physics |
ID Code: | 30341 |
Deposited By: | Mr UPT Perpus 1 |
Deposited On: | 27 Oct 2011 13:06 |
Last Modified: | 27 Oct 2011 13:06 |