Perbandingan penggunaan grid dan teknik celah udara serta pengaruhnya terhadap pengurangan radiasi hambur

Syarifudin , Syarifudin (2002) Perbandingan penggunaan grid dan teknik celah udara serta pengaruhnya terhadap pengurangan radiasi hambur. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

2451Kb
[img]
Preview
PDF
17Kb
[img]
Preview
PDF
355Kb
[img]
Preview
PDF
563Kb
[img]
Preview
PDF
426Kb
[img]
Preview
PDF
929Kb
[img]
Preview
PDF
809Kb
[img]PDF
Restricted to Repository staff only

647Kb
[img]
Preview
PDF
337Kb
[img]
Preview
PDF
337Kb
[img]
Preview
PDF
744Kb

Abstract

Telah dilakukan penelitian perbandingan penggunaan grid dan teknik celah udara serta pengaruhnya terhadap pengurangan radiasi hambur. Penelitian dilakukan dengan menggunakan grid linear yang berbeda rasio, terdiri dari. rasio 6 : 1, 10 : 1 dan 12 :1. Celah udara dibuat dengan mengatur jarak antara obyek dengan film sejauh 30 cm dan dilakukan penyinaran setiap interval 5 cm. Obyek penelitian berupa dua buah koin timbal masing-masing berdiameter 3 cm dan ketebalan 2 mm yang diletakkan dalarn wadah berukuran 22 cm x 16 cm x 18 cm dengan ketinggian air 16 cm. Faktor paparan yang digunakan adalah variasi tegangan tabung dan 50 kV sampai 120 kV dengan kenaikan interval tiap 10 kV, anus tabung 100 mA dan waktu penyinaran 0,40 detik serta jarak fokus ke film 90 cm. Penyinaran dilakukan tanpa grid terlebih dahulu dan hasilnya dibandingkan dengan penyinaran menggunakan grid serta variasi celah udara untuk diketahui tingkat perbaikan kontrasnya. Hasil penelitian menunjukkan bahwa diperoleh kesetaraan densitas dan kontras radiograf antara pemakaian grid rasio 6 1 dengan celah udara 20 cm pada faktor paparan 90 kV 40 mAs dan teknik celah udara 30 cm setara dengan grid rasio 10 : 1 dan 12 : 1 pada faktor paparan 100 kV 40 mAs. It have been done the comparitions experiment of using the grid and the air gap tecnique and the influence to the scatter radiation reducing. This experiment was done with using various linear grid with different ratio, such as 6 : 1, 10 : 1 and 12 : 1 ratio. Using air gap was done with drive the distance between object with interval 5 cm. The experimental object are two Pb coins. They have diameter 3 cm and the thickness 2 mm that put in the plastic box with size 12 cm X 16 cm X 18 cm with water high 16 cm. Exposure factor that using is tube. voltage Variation begin 50 kV till 120 kV, with interval increasing each 10 kV, tube current 100 mA and the exposure time 0,40 second. So, the focus distance to the film 90 cm. Exposure was done without grid first and the result was compare with sliding use grid with air gab variation to know the rate contrast make up. The experiment results show that get the density equelibrium and radiograph density between using grid with ratio 10 : 1 and 12 : 1 with air gap 30 cm at 100 kV 40 mAs and ratio grid 6 : 1 equivalen with air gap 20 cm at 90 kV 40 mAs. The rate magnification image is 1,3 % at the air gap 20 cm and 1,5 % at air gab 30 cm.

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QC Physics
Divisions:Faculty of Science and Mathematics > Department of Physics
ID Code:30340
Deposited By:Mr UPT Perpus 1
Deposited On:27 Oct 2011 12:58
Last Modified:27 Oct 2011 12:58

Repository Staff Only: item control page