Pengaturan penguat dan penganalisa salur tunggal untuk pencacahan radio formaka Co - 57

Harmoko , Udi (1996) Pengaturan penguat dan penganalisa salur tunggal untuk pencacahan radio formaka Co - 57. Undergraduate thesis, FMIPA UNDIP.

[img]PDF
Restricted to Repository staff only

1899Kb
[img]
Preview
PDF
16Kb
[img]
Preview
PDF
345Kb
[img]
Preview
PDF
437Kb
[img]
Preview
PDF
396Kb
[img]
Preview
PDF
671Kb
[img]
Preview
PDF
677Kb
[img]PDF
Restricted to Repository staff only

573Kb
[img]
Preview
PDF
349Kb
[img]
Preview
PDF
337Kb
[img]
Preview
PDF
473Kb

Abstract

Telah dilakukan penelitian pengaturan penguat dan penganalisa salur tunggal untuk sistem pencacah gamma pada satu pilihan sumber radiofarmaka Co-57. Sebagai sumber kalibrator_dipakai sumber Cs-137. Pulsa sumber Co-57 dikuatkan 264,2 kali dan pulses sumber Cs-137 dikuatkan 34,1 kali, sehingga puncak serap¬an fotolistrik kedua sumber tersebut terletak pada kanal yang sama. Dengan mengatur jendela penganalisa salur tunggal pada pencacahan Co-57 yaitu batas ambang bawah (LLD) = 2,8 Volt dan batas'ambang atas (ULD) = 3,2 Volt. Sedangkan untuk sumber cs-137, batas ambang bawah (LLD) = 2,5 Volt dan batas ambang atas (ULD) = 3,2 Volt, sehingga diperoleh jumlah cacah masing - masing sumber (Cs-137 dan Co-57) adalah sama untuk setiap pencacahan kedua sumber tersebut saat aktivitas keduanya sama, yang merupakan prinsip dasar penelitian ini. Dari pengujian menggunakan sumber Co-57 yang berak-tivitas 1,36 pCi didapatkan hasil yang mendekati harga sesungguhnya yaitu 1,36 + 0,02 pCi. It have been researched the gain of amplifier and single channel analyzer's window for Gamma Counter system on a Radiopharmacitical Co-57 choice and the Cs-137 as calibration source. The Co-57 source pulse have to be amplified by 264.2 -times and Cs-137 by 34.1 times to locate both peak area on the same channel. The single channel analyzer's window for counting Co-57 -be arranged by Low Level Discriminator at 2,8 Volt and Upper Level Discriminator at 3.2 Volt. Furthermore for counting Cs-137, The Low Level Discriminator at 2.5 Volt and Upper Level Discriminator at 3.2 Volt. So it would reached for principle of the instrument designing, that every counts both source (Co-57 or Cs-137) wich have the same activity will produce the same counting rate too. The result of designing have been tested by Co-57 source at 1.36 pCi produced the same limited really value was 1.36 ± 0.02 pCi.

Item Type:Thesis (Undergraduate)
Subjects:Q Science > QC Physics
Divisions:Faculty of Science and Mathematics > Department of Physics
ID Code:30287
Deposited By:Mr UPT Perpus 1
Deposited On:26 Oct 2011 07:58
Last Modified:26 Oct 2011 07:58

Repository Staff Only: item control page