Bagus, Yuliansyah and Darmanto, Seno (2011) MODIFIKASI DAN PERHITUNGAN PERPINDAHAN KALOR PADA ALAT PENUKAR KALOR RADIATOR “DEBIT ALIRAN AIR 0,002 M3/MENIT” ( MODIFICATION AND CALCULATION HEAT TRANSFER HEAT EXCHANGER ON RADIATOR "FLOWING WATER DISCHARGE 0.002 M3/MENIT" ). Undergraduate thesis, D3 Teknik Mesin.
| PDF 215Kb |
Abstract
Alat penukar kalor merupakan suatu peralatan dimana terjadi perpindahan panas dari satu fluida yang temperaturnya tinggi ke fluida yang temperaturnya lebih rendah. Kemampuan sistem alat penukar kalor dengan menggunakan fluida cair sangat tergantung pada kemampuan fluida cair dalam menyerap kalor dan melepaskannya ke udara melalui radiator. Jumlah kalor yang dipindahkan meningkat sejalan dengan peningkatan perbedaan temperatur masuk dengan keluar radiator. Pengujian dilakukan menggunakan alat uji yang berguna sebagai simulator pendingingan pada kendaraan. Penukar kalor yang digunakan adalah radiator, sumber panasnya berasal dari heater listrik, sedangkan aliran fluida cair dan angin diperoleh dengan menggunakan pompa air dan kipas listrik. Penelitian alat penukar kalor radiator dilakukan untuk mengetahui efektifitas radiator, beda suhu rata-rata radiator dan besar nilai perpindahan kalor menyeluruh yang terjadi pada radiator. Dari hasil pengujian, nilai efektifitas radiator berbanding lurus dengan kecepatan udara yang melintas melewati radiator, sedangkan untuk perpindahan kalor menyeluruhnya tidak konstan terhadap kecepatan udara yang berhembus melewati radiator yaitu pada suhu 600C perpindahan kalor paling optimal terjadi pada kecepatan udara 0,677 m/s, pada suhu 650C perpindahan kalor menyeluruh paling optimal pada kecepatan udara 1,2 m/s , pada suhu 700C perpindahan kalor menyeluruh paling optimal pada kecepatan udara 1,033 m/s dan pada suhu 80oC perpindahan kalor menyeluruh paling optimal pada kecepatan udara 1,2 m/s. Kata kunci : Alat Penukar Kalor Heat exchanger is an instrumentation where there is heat transfer from a high temperature fluid to the fluid temperature is lower. The ability of the system heat exchanger using liquid fluid is highly dependent on the ability of liquid fluid to absorb heat and release it into the air through the radiator. The amount of heat transferred increases with increasing temperature difference into the radiator out. Tests carried out using the instrument test is useful as a simulator cooler on vehicles. Heat exchanger used is a radiator, the heat source comes from an electric heater, while the liquid fluid flow and wind obtained by using a water pump and electric fan. Research radiator heat exchanger is performed to determine the effectiveness of the radiator, log mean temperature difference of the radiator and the overall heat transfer that occurs in the radiator. From the test results, the effectivity of the radiator is proportional with the velocity of air passing through the radiator, but for the overall heat transfer is not constant with the speed of air that blows through the radiator is at temperature 600C the most optimal heat transfer occurs in air velocity 0.667 m/s, at temperature 650C the optimal overall heat transfer is at air velocity 1.2 m/s, at temperature of 700C optimal overall heat transfer at is air velocity 1.033 m/s and at temperature of 800C optimal overall heat transfer is at air velocity 1.2 m/s Keyword : Heat Exchanger
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Faculty of Engineering > Diploma in Mechanical Engineering Faculty of Engineering > Diploma in Mechanical Engineering |
ID Code: | 28584 |
Deposited By: | INVALID USER |
Deposited On: | 11 Jul 2011 13:43 |
Last Modified: | 11 Jul 2011 13:43 |
Repository Staff Only: item control page