Oktavia, Astrid (2007) PENGGUNAAN INTERFEROMETER MICHELSON UNTUK MENENTUKAN PANJANG GELOMBANG LASER DIODA DAN INDEKS BIAS BAHAN TRANSPARAN. In: Seminar Tugas Akhir S1 Jurusan Fisika FMIPA UNDIP . (Unpublished)
| PDF 37Kb |
Abstract
Interferometer Michelson method has been used to measure wavelength of dioda laser, refractive index of glass and air . Interferometer beforehand calibrated by source of He-Ne laser then determined dioda laser wavelength by shifting movable mirror . index refractive of glass determined with variation angle inclination of glass, and index refractive of air obtained with pressure variation every increase 10kPa at cell vacuum Result of measurement for the wavelength of red dioda laser l = (660.5±1.6)nm and green dioda laser l = (530.5 ± 2.7) nm . For the measurement of index refractive of glass used glass with thickness 5.64 mm and obtained result (1.49 ± 0.06 ) when used He-Ne laser and (1.52 ± 0.01)when used green dioda laser. At determinate index refractive of air, appear change linear for index refractive air cause change pressure 5 n 1 0.2166x10 p − = + .
Item Type: | Conference or Workshop Item (Other) |
---|---|
Uncontrolled Keywords: | Interferometer Michelson, wavelength, index refractive. |
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Science and Mathematics > Department of Physics |
ID Code: | 2641 |
Deposited By: | INVALID USER |
Deposited On: | 14 Dec 2009 15:45 |
Last Modified: | 14 Dec 2009 15:45 |
Repository Staff Only: item control page