PEMANFAATAN PANAS GAS BUANG MOTOR DIESEL 7 PK SEBAGAI PEMANAS AIR ( UTILIZATION OF EXHAUST HEAT 7 HP DIESEL MOTOR AS THE IMPOSITION OF WATER HEATER )

Agung, Priyadi and Angga, Nor Ikhwan and Arief, Pramudianto and Arif, Ripmawanto and Murni, Murni (2010) PEMANFAATAN PANAS GAS BUANG MOTOR DIESEL 7 PK SEBAGAI PEMANAS AIR ( UTILIZATION OF EXHAUST HEAT 7 HP DIESEL MOTOR AS THE IMPOSITION OF WATER HEATER ). Undergraduate thesis, DIII Teknik Mesin Fakultas Teknik.

[img]
Preview
PDF
148Kb

Abstract

Tujuan pelaksanaan tugas akhir ini adalah mengetahui mengetahui perpindahan panas yang terjadi pada Heat Exchanger yang dipasang secara helical pada knalpot. Knalpot dimodifikasi sedemikian rupa agar aliran air dapat mengalir didalamnya. Perpindahan panas yang terjadi dapat diukur dari peningkatan temperatur yang terjadi pada air yang dialirkan pada Heat Exchanger dibanding dengan nilai kalor bahan bakar dari konsumsi bahan bakar yang terjadi. Dari hasil pengujian perpindahan panas yang terjadi pada Heat Exchanger dengan spesifikasi aliran air yang sama dapat diperoleh data sebagai berikut: Pada pembebanan 451 Watt, perpindahan kalor yang terjadi 1,754 Kj/s, konsumsi bahan bakar liter/jam, laju perpindahan massa gas buang 0,01888 kg/s, dan efisiensi kalor berbanding dengan nilai kalor gas buang adalah . Maka dapat diambil kesimpulan bahwa perpindahan kalor, konsumsi bahan bakar, laju aliran massa gas buang dan efisiensi paling besar terjadi pada pembebanan yang lebih tinggi yaitu 1386 Watt. Kata kunci : Perpindahan Kalor, Heat Exchanger. The aim of this thesis is to investigate hot transfer that happened in Heat Exchanger attached by helical system inside exhaust pipe. Exhaust pipe of Modification in such a manner in order to the current can emit a stream of in it. Heat transfer that happened is measurable from improvement of temperature that happened at water conducted inside Heat Exchanger compared to with value of kalori of fuel from consumption of fuel that happened. From result examination of hot transfer that happened inside Heat Exchanger by the specification of current equal obtainable by the following data.: At encumbering 451 Watt, transfer kalor that happened 1,754 Kj/S, consume fuel 1,384 liter/hours, fast of flow mass gas is 0,01888 kg/s, and heat efficiency to compare with value flow mass gass 35,81 %. Hence can be taken by conclusion that heat transfer, consume fuel, flow mass gas and the became of biggest efficiency of higher level encumbering that is 1386 Watt. Key word : heat Transfer, Heat Exchanger

Item Type:Thesis (Undergraduate)
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Faculty of Engineering > Diploma in Mechanical Engineering
Faculty of Engineering > Diploma in Mechanical Engineering
ID Code:26344
Deposited By:INVALID USER
Deposited On:15 Mar 2011 10:40
Last Modified:15 Mar 2011 10:40

Repository Staff Only: item control page